Khởi động từ SIEMENS 3RT6026-1AN20. product brand name: SIRIUS; product designation: Power contactor; product type designation: 3RT6.
品番
3RT6026-1AN20
単位
Cái
供給状況
Liên hệ báo giá
必要数量 (Cái)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | 3RT6026-1AN20 |
| Tên gọi chính hãng | Contactor AC 220 V 50/60 HZ AC3 11 kW 400 V AUX contacts 1 NO +1 NC 3-pole, size S0 screw terminal |
| product brand name | SIRIUS |
| product designation | Power contactor |
| product type designation | 3RT6 |
| General technical data / size of contactor | S0 |
| General technical data / product extension auxiliary switch | Yes |
| General technical data / power loss [W] for rated value of the current / at AC in hot operating state per pole | 1.9 W |
| General technical data / power loss [W] for rated value of the current / without load current share typical | 2.62 W |
| General technical data / type of calculation of power loss current-dependent | quadratic |
| General technical data / insulation voltage rated value | 690 V |
| General technical data / degree of pollution | 3 |
| General technical data / surge voltage resistance rated value | 6 kV |
| General technical data / maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 | 400 V |
| General technical data / shock resistance at rectangular impulse / at AC | 8,3 g / 5 ms, 5,3 g / 10 ms |
| General technical data / shock resistance with sine pulse / at AC | 13,5 g / 5 ms, 8,3 g / 10 ms |
| General technical data / mechanical service life (operating cycles) / of contactor typical | 10 000 000 |
| General technical data / mechanical service life (operating cycles) / of the contactor with added auxiliary switch block typical | 10 000 000 |
| General technical data / Substance Prohibitance (day/month/year) | 05/01/2012 |
| General technical data / Net Weight | 0.39 kg |
| Ambient conditions / installation altitude at height above sea level maximum | 2 000 m |
| Ambient conditions / ambient temperature / during operation | -25 ... +60 °C |
| Ambient conditions / ambient temperature / during storage | -55 ... +80 °C |
| Main circuit / number of poles for main current circuit | 3 |
| Main circuit / number of NO contacts for main contacts | 3 |
| Main circuit / number of NC contacts for main contacts | 0 |
| Main circuit / operating voltage / at AC-3 rated value maximum | 690 V |
| Main circuit / operating voltage / at AC-3e rated value maximum | 690 V |
| operational current / at AC-1 up to 690 V / at ambient temperature 40 °C rated value | 40 A |
| at ambient temperature 60 °C rated value | 35 A |
| at AC-3 / at 400 V rated value | 25 A |
| at AC-3 / at 690 V rated value | 13 A |
| at AC-3e / at 400 V rated value | 25 A |
| at AC-3e / at 690 V rated value | 13 A |
| 1 / at 60 °C minimum permissible | 10 mm² |
| 1 / at 40 °C minimum permissible | 10 mm² |
| AC-4 / at 400 V rated value | 9 A |
| AC-4 / at 690 V rated value | 9 A |
| operating power / at AC-1 / at 230 V rated value | 13.3 kW |
| operating power / at AC-1 / at 230 V at 60 °C rated value | 13.3 kW |
| operating power / at AC-1 / at 400 V at 60 °C rated value | 23 kW |
| operating power / at AC-1 / at 690 V at 60 °C rated value | 40 kW |
| operating power / at AC-3 / at 230 V rated value | 5.5 kW |
| operating power / at AC-3 / at 400 V rated value | 11 kW |
| operating power / at AC-3 / at 690 V rated value | 11 kW |
| operating power / at AC-3e / at 230 V rated value | 5.5 kW |
| operating power / at AC-3e / at 400 V rated value | 11 kW |
| operating power / at AC-3e / at 690 V rated value | 11 kW |
| 4 / at 400 V rated value | 4.4 kW |
| 4 / at 690 V rated value | 7.7 kW |
| short-time withstand current in cold operating state up to 40 °C limited to 10 s switching at zero current maximum | 200 A |
| no-load switching frequency / at AC | 5 000 1/h |
| operating frequency / at AC-1 maximum | 1 000 1/h |
| operating frequency / at AC-3 maximum | 750 1/h |
| operating frequency / at AC-3e maximum | 750 1/h |
| operating frequency / at AC-4 maximum | 250 1/h |
| Control circuit/ Control / type of voltage of the control supply voltage | AC |
| Control circuit/ Control / control supply voltage at AC / at 50 Hz rated value | 220 V |
| Control circuit/ Control / control supply voltage at AC / at 60 Hz rated value | 220 V |
| Control circuit/ Control / magnet coil at AC / at 50 Hz | 0.8 ... 1.1 |
| Control circuit/ Control / magnet coil at AC / at 60 Hz | 0.85 ... 1.1 |
| Control circuit/ Control / apparent pick-up power of magnet coil at AC / at 50 Hz | 81 V·A |
| Control circuit/ Control / apparent pick-up power of magnet coil at AC / at 60 Hz | 79 V·A |
| Control circuit/ Control / inductive power factor with closing power of the coil / at 50 Hz | 0.72 |
| Control circuit/ Control / inductive power factor with closing power of the coil / at 60 Hz | 0.74 |
| Control circuit/ Control / apparent holding power of magnet coil at AC / at 50 Hz | 10.5 V·A |
| Control circuit/ Control / apparent holding power of magnet coil at AC / at 60 Hz | 8.5 V·A |
| inductive power factor with the holding power of the coil / at 50 Hz | 0.25 |
| inductive power factor with the holding power of the coil / at 60 Hz | 0.28 |
| Auxiliary circuit / number of NC contacts for auxiliary contacts instantaneous contact | 1 |
| Auxiliary circuit / number of NO contacts for auxiliary contacts instantaneous contact | 1 |
| Auxiliary circuit / operational current at AC-12 maximum | 10 A |
| Auxiliary circuit / operational current at AC-15 / at 230 V rated value | 10 A |
| Auxiliary circuit / operational current at AC-15 / at 400 V rated value | 3 A |
| Auxiliary circuit / operational current at AC-15 / at 690 V rated value | 1 A |
| Auxiliary circuit / operational current at DC-12 / at 24 V rated value | 6 A |
| Auxiliary circuit / operational current at DC-12 / at 110 V rated value | 3 A |
| Auxiliary circuit / operational current at DC-12 / at 220 V rated value | 1 A |
| Auxiliary circuit / operational current at DC-13 / at 24 V rated value | 6 A |
| Auxiliary circuit / operational current at DC-13 / at 110 V rated value | 1 A |
| Auxiliary circuit / operational current at DC-13 / at 220 V rated value | 0.3 A |
| Auxiliary circuit / contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| UL/CSA ratings / yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value | 15 hp |
| design of the fuse link / for short-circuit protection of the main circuit / with type of coordination 1 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 100 A |
| design of the fuse link / for short-circuit protection of the main circuit / with type of coordination 2 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A |
| Short-circuit protection / design of the fuse link / for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
| Installation/ mounting/ dimensions / mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
| Installation/ mounting/ dimensions / fastening method side-by-side mounting | Yes |
| Installation/ mounting/ dimensions / fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022 |
| Installation/ mounting/ dimensions / height | 85 mm |
| Installation/ mounting/ dimensions / width | 45 mm |
| Installation/ mounting/ dimensions / depth | 97 mm |
| required spacing / with side-by-side mounting / at the side | 0 mm |
| Connections/ Terminals / type of electrical connection / for main current circuit | screw-type terminals |
| Connections/ Terminals / type of electrical connection / for auxiliary and control circuit | screw-type terminals |
| Connections/ Terminals / type of connectable conductor cross-sections for main contacts / solid or stranded | 2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections for main contacts / finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² |
| type of connectable conductor cross-sections / for auxiliary contacts / solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| type of connectable conductor cross-sections / for auxiliary contacts / finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for AWG cables for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14) |
| Safety related data / product function mirror contact according to IEC 60947-4-1 | Yes |
| Safety related data / protection class IP on the front according to IEC 60529 | IP20 |