品番: 3RA2816-0EW20
- 単位
- Chưa cập nhật
コンテンツを読み込み中…
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。

Bộ điều khiển PLC SIEMENS 6ES7313-5BG04-0AB0. General information / Tên kiểu sản phẩm: CPU 313C; General information / HW functional status: 01; General information / Firmware version: V3.3.
品番
6ES7313-5BG04-0AB0
単位
Chưa cập nhật
供給状況
Liên hệ báo giá
必要数量 (Chưa cập nhật)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | 6ES7313-5BG04-0AB0 |
| Tên gọi chính hãng | ***spare part*** SIMATIC S7-300, CPU 313C, compact CPU with MPI, 24 DI/16 DO, 4 AI, 2 AO, 1 Pt100, 3 high-speed counters (30 kHz), integrated power supply 24 V DC, work memory 128 KB, front connector (2x 40-pole) and Micro Memory Card required |
| General information / Tên kiểu sản phẩm | CPU 313C |
| General information / HW functional status | 01 |
| General information / Firmware version | V3.3 |
| General information / Engineering with / Programming package | STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Supply voltage / external protection for power supply lines (recommendation) | Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A |
| Supply voltage / Mains buffering / Mains/voltage failure stored energy time | 5 ms |
| Supply voltage / Mains buffering / Repeat rate, min. | 1 s |
| Load voltage L+ / Digital inputs / Rated value (DC) | 24 V |
| Load voltage L+ / Digital inputs / Reverse polarity protection | Yes |
| Load voltage L+ / Digital outputs / Rated value (DC) | 24 V |
| Load voltage L+ / Digital outputs / Reverse polarity protection | No |
| Input current / Current consumption (rated value) | 650 mA |
| Input current / Current consumption (in no-load operation), typ. | 150 mA |
| Input current / Inrush current, typ. | 5 A |
| Input current / I²t | 0.7 A²·s |
| Input current / Digital inputs / from load voltage L+ (without load), max. | 80 mA |
| Input current / Digital outputs / from load voltage L+, max. | 50 mA |
| Power loss / Power loss, typ. | 12 W |
| Storage / Work memory / integrated | 128 kbyte |
| Storage / Work memory / expandable | No |
| Storage / Load memory / Plug-in (MMC) | Yes |
| Plug-in (MMC), max. | 8 Mbyte |
| Data management on MMC (after last programming), min. | 10 a |
| Backup / present | Yes; Guaranteed by MMC (maintenance-free) |
| Backup / without battery | Yes; Program and data |
| CPU processing times / for bit operations, typ. | 0.07 μs |
| CPU processing times / for word operations, typ. | 0.15 μs |
| CPU processing times / for fixed point arithmetic, typ. | 0.2 μs |
| CPU processing times / for floating point arithmetic, typ. | 0.72 μs |
| CPU-blocks / Number of elements (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
| CPU-blocks / DB / Number, max. | 1 024; Number range: 1 to 16000 |
| CPU-blocks / DB / Size, max. | 64 kbyte |
| CPU-blocks / FB / Number, max. | 1 024; Number range: 0 to 7999 |
| CPU-blocks / FB / Size, max. | 64 kbyte |
| CPU-blocks / FC / Number, max. | 1 024; Number range: 0 to 7999 |
| CPU-blocks / FC / Size, max. | 64 kbyte |
| CPU-blocks / OB / Number, max. | see instruction list |
| CPU-blocks / OB / Size, max. | 64 kbyte |
| CPU-blocks / OB / Number of free cycle OBs | 1; OB 1 |
| CPU-blocks / OB / Number of time alarm OBs | 1; OB 10 |
| CPU-blocks / OB / Number of delay alarm OBs | 2; OB 20, 21 |
| CPU-blocks / OB / Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 |
| CPU-blocks / OB / Number of process alarm OBs | 1; OB 40 |
| CPU-blocks / OB / Number of startup OBs | 1; OB 100 |
| CPU-blocks / OB / Number of asynchronous error OBs | 4; OB 80, 82, 85, 87 |
| CPU-blocks / OB / Number of synchronous error OBs | 2; OB 121, 122 |
| CPU-blocks / Nesting depth / per priority class | 16 |
| CPU-blocks / Nesting depth / additional within an error OB | 4 |
| Counters, timers and their retentivity / S7 counter / Number | 256 |
| S7 counter / Retentivity / adjustable | Yes |
| S7 counter / Retentivity / preset | Z 0 to Z 7 |
| S7 counter / Counting range / lower limit | 0 |
| S7 counter / Counting range / upper limit | 999 |
| Counters, timers and their retentivity / IEC counter / present | Yes |
| Counters, timers and their retentivity / IEC counter / Type | SFB |
| Counters, timers and their retentivity / IEC counter / Number | Unlimited (limited only by RAM capacity) |
| Counters, timers and their retentivity / S7 timer / Number | 256 |
| S7 timer / Retentivity / adjustable | Yes |
| S7 timer / Retentivity / preset | No retentivity |
| S7 timer / Time range / lower limit | 10 ms |
| S7 timer / Time range / upper limit | 9 990 s |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
| Data areas and their retentivity / Retentive data area (incl. timers, counters, flags), max. | 64 kbyte |
| Data areas and their retentivity / Flag / Size, max. | 256 byte |
| Data areas and their retentivity / Flag / Retentivity available | Yes; MB 0 to MB 255 |
| Data areas and their retentivity / Flag / Retentivity preset | MB 0 to MB 15 |
| Data areas and their retentivity / Flag / Number of clock memories | 8; 1 memory byte |
| Data areas and their retentivity / Data blocks / Retentivity adjustable | Yes; via non-retain property on DB |
| Data areas and their retentivity / Data blocks / Retentivity preset | Yes |
| Data areas and their retentivity / Local data / per priority class, max. | 32 kbyte; Max. 2048 bytes per block |
| Address area / I/O address area / Inputs | 1 024 byte |
| Address area / I/O address area / Outputs | 1 024 byte |
| I/O address area / of which distributed / Inputs | none |
| I/O address area / of which distributed / Outputs | none |
| Address area / Process image / Inputs | 1 024 byte |
| Address area / Process image / Outputs | 1 024 byte |
| Address area / Process image / Inputs, adjustable | 1 024 byte |
| Address area / Process image / Outputs, adjustable | 1 024 byte |
| Address area / Process image / Inputs, default | 128 byte |
| Address area / Process image / Outputs, default | 128 byte |
| Address area / Digital channels / Inputs | 1 016 |
| Address area / Digital channels / of which central | 1 016; 1 008 |
| Address area / Digital channels / Outputs | 1 008 |
| Address area / Analog channels / Inputs | 253 |
| Address area / Analog channels / of which central | 253; 250 |
| Address area / Analog channels / Outputs | 250 |
| Hardware configuration / Number of expansion units, max. | 3 |
| Hardware configuration / Number of DP masters / integrated | none |
| Hardware configuration / Number of DP masters / via CP | 4 |
| Hardware configuration / Number of operable FMs and CPs (recommended) / FM | 8 |
| Hardware configuration / Number of operable FMs and CPs (recommended) / CP, PtP | 8 |
| Hardware configuration / Number of operable FMs and CPs (recommended) / CP, LAN | 6 |
| Hardware configuration / Rack / Racks, max. | 4 |
| Hardware configuration / Rack / Modules per rack, max. | 8; In rack 3 max. 7 |
| Time of day / Clock / Hardware clock (real-time) | Yes |
品番: 3RA2816-0EW20
品番: 3RT2035-1NB30
品番: 6MF2805-0AA00
品番: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.