Module truyền thông SIEMENS 6GK7343-1CX10-0XE0. product type designation: CP 343-1 Lean; product brand name: SIMATIC NET; Technical Product Detail Page: https://i.siemens.com/1P6GK7343-1CX10-0XE0.
品番
6GK7343-1CX10-0XE0
単位
Cái
供給状況
Liên hệ báo giá
必要数量 (Cái)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | 6GK7343-1CX10-0XE0 |
| Tên gọi chính hãng | - - spare part - - communications processor CP 343-1 Lean for connection of SIMATIC S7-300 to Industrial Ethernet via TCP/IP and UDP, multicast, send/receive with and without RFC1006, fetch/ write, S7 communication (server), PROFINET IO device integrated 2-port switch ERTEC 200, module exchange without PG, SNMP diagnostics, initialization via LAN, 2x RJ45 connection for LAN with 10/100 Mbps. |
| product type designation | CP 343-1 Lean |
| product brand name | SIMATIC NET |
| Technical Product Detail Page | https://i.siemens.com/1P6GK7343-1CX10-0XE0 |
| transfer rate / transfer rate / at the 1st interface | 10 ... 100 Mbit/s |
| interfaces / number of interfaces / according to Industrial Ethernet | 2 |
| interfaces / number of electrical connections / at the 1st interface / according to Industrial Ethernet | 2 |
| interfaces / number of electrical connections / for power supply | 1 |
| interfaces / type of electrical connection / of Industrial Ethernet interface | RJ45 port |
| interfaces / type of electrical connection / at the 1st interface / according to Industrial Ethernet | RJ45 port |
| interfaces / type of electrical connection / for power supply | 2-pole plugable terminal block |
| supply voltage, current consumption, power loss / type of voltage / of the supply voltage | DC |
| supply voltage, current consumption, power loss / supply voltage / 1 / from backplane bus | 5 V |
| supply voltage, current consumption, power loss / supply voltage | 24 V |
| supply voltage, current consumption, power loss / supply voltage / external | 24 V |
| supply voltage, current consumption, power loss / supply voltage / external / at DC / rated value | 24 V |
| supply voltage, current consumption, power loss / relative positive tolerance / at DC / at 24 V | 20 % |
| supply voltage, current consumption, power loss / relative negative tolerance / at DC / at 24 V | 15 % |
| supply voltage, current consumption, power loss / consumed current / from backplane bus / at DC / at 5 V / typical | 0.2 A |
| supply voltage, current consumption, power loss / consumed current / from external supply voltage / at DC / at 24 V / typical | 0.16 A |
| supply voltage, current consumption, power loss / consumed current / from external supply voltage / at DC / at 24 V / maximum | 0.2 A |
| supply voltage, current consumption, power loss / power loss [W] | 5.8 W |
| ambient conditions / ambient temperature / for vertical installation / during operation | 0 ... 40 °C |
| ambient conditions / ambient temperature / for horizontally arranged busbars / during operation | 0 ... 60 °C |
| ambient conditions / ambient temperature / during storage | -40 ... +70 °C |
| ambient conditions / ambient temperature / during transport | -40 ... +70 °C |
| ambient conditions / relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % |
| ambient conditions / protection class IP | IP20 |
| design, dimensions and weights / module format | Compact module S7-300 single width |
| design, dimensions and weights / width | 40 mm |
| design, dimensions and weights / height | 125 mm |
| design, dimensions and weights / depth | 120 mm |
| design, dimensions and weights / net weight | 0.22 kg |
| design, dimensions and weights / fastening method / S7-300 rail mounting | Yes |
| performance data / open communication / number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 |
| performance data / open communication / data volume / as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
| performance data / open communication / data volume / as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
| performance data / open communication / data volume / as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum | 2 Kibyte |
| performance data / open communication / number of Multicast stations | 8 |
| performance data / S7 communication / number of possible connections / for S7 communication / maximum | 4 |
| performance data / S7 communication / service / of SIMATIC communication / as server | Yes |
| performance data / multi-protocol mode / number of active connections / with multi-protocol mode | 12 |
| performance data / PROFINET communication / as PN IO controller / product function / PROFINET IO controller | No |
| performance data / PROFINET communication / as PN IO device / product function / PROFINET IO device | Yes |
| performance data / PROFINET communication / as PN IO device / data volume / as user data for input variables / as PROFINET IO device / maximum | 512 byte |
| performance data / PROFINET communication / as PN IO device / data volume / as user data for output variables / as PROFINET IO device / maximum | 512 byte |
| performance data / PROFINET communication / as PN IO device / data volume / as user data for input variables / for each sub-module as PROFINET IO device | 240 byte |
| performance data / PROFINET communication / as PN IO device / data volume / as user data for output variables / for each sub-module as PROFINET IO device | 240 byte |
| performance data / PROFINET communication / as PN IO device / data volume / as user data for the consistency area for each sub- module | 240 byte |
| performance data / PROFINET communication / as PN IO device / number of submodules / per PROFINET IO-Device | 32 |
| performance data / telecontrol / protocol / is supported / TCP/IP | Yes |
| product functions / management, configuration, engineering / product function / MIB support | Yes |
| product functions / management, configuration, engineering / protocol / is supported / SNMP v1 | Yes |
| product functions / management, configuration, engineering / protocol / is supported / DCP | Yes |
| product functions / management, configuration, engineering / protocol / is supported / LLDP | Yes |
| product functions / management, configuration, engineering / configuration software / required | STEP 7 V5.4 or higher / STEP 7 Professional V11 (TIA Portal) or higher |
| product functions / management, configuration, engineering / identification & maintenance function / I&M0 - device-specific information | Yes |
| product functions / management, configuration, engineering / identification & maintenance function / I&M1 - higher level designation/location designation | Yes |
| product functions / management, configuration, engineering / product function / is supported / identification link | Yes; acc. to IEC 61406-1:2022 |
| product functions / diagnostics / product function / web-based diagnostics | Yes |
| product functions / switch / product feature / switch | Yes |
| product functions / switch / product function / switch-managed | No |
| product functions / switch / product function / with IRT / PROFINET IO switch | No |
| product functions / switch / product function / configuration with STEP 7 | Yes |
| product functions / redundancy / product function / ring redundancy | Yes |
| product functions / redundancy / product function / redundancy manager | No |
| product functions / redundancy / protocol / is supported / Media Redundancy Protocol (MRP) | Yes |
| product functions / security / product function / password protection for Web applications | No |
| product functions / security / product function / ACL - IP-based | Yes |
| product functions / security / product function / ACL - IP-based for PLC/routing | No |
| product functions / security / product function / switch-off of non-required services | Yes |
| product functions / security / product function / blocking of communication via physical ports | Yes |
| product functions / security / product function / log file for unauthorized access | No |
| product functions / time / product function / SICLOCK support | Yes |
| product functions / time / product function / pass on time synchronization | Yes |
| product functions / time / protocol / is supported / NTP | Yes |
| further information / internet links / internet link / to website: Selection guide for cables and connectors | https://support.industry.siemens.com/cs/ww/en/view/109766358 |
| further information / internet links / internet link / to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| further information / internet links / internet link / to website: Industrial communication | https://www.siemens.com/simatic-net |
| further information / internet links / internet link / to web page: SiePortal | https://sieportal.siemens.com/ |
| further information / internet links / internet link / to website: Image database | https://www.automation.siemens.com/bilddb |
| further information / internet links / internet link / to website: CAx-Download-Manager | https://siemens.com/cax |
| further information / internet links / internet link / to website: Industry Online Support | https://support.industry.siemens.com |
| security information / security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. |
品番: 3RA2816-0EW20
品番: 3RT2035-1NB30
品番: 6MF2805-0AA00
品番: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.