品番: 3RA2816-0EW20
- 単位
- Chưa cập nhật
コンテンツを読み込み中…
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。

Aptomat SIEMENS 3RV2021-4AA10. product brand name: SIRIUS; product designation: Circuit breaker; design of the product: For motor protection.
品番
3RV2021-4AA10
単位
Chưa cập nhật
供給状況
見積はお問い合わせください
必要数量 (Chưa cập nhật)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | 3RV2021-4AA10 |
| Tên gọi chính hãng | Circuit breaker size S0 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A screw terminal Standard switching capacity |
| product brand name | SIRIUS |
| product designation | Circuit breaker |
| design of the product | For motor protection |
| product type designation | 3RV2 |
| General technical data / Product equipment of circuit breaker for motor protection complete unit with protection device | Yes |
| General technical data / size of the circuit-breaker | S0 |
| General technical data / size of contactor can be combined company-specific | S00, S0 |
| General technical data / product function disconnector functionality | Yes |
| General technical data / product extension auxiliary switch | Yes |
| General technical data / power loss [W] for rated value of the current / at AC in hot operating state | 9.25 W |
| General technical data / power loss [W] for rated value of the current / at AC in hot operating state per pole | 3.1 W |
| General technical data / type of calculation of power loss current-dependent | quadratic |
| General technical data / insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| General technical data / surge voltage resistance rated value | 6 kV |
| General technical data / maximum permissible voltage for protective separation / in networks with ungrounded star point between main and auxiliary circuit | 400 V |
| General technical data / maximum permissible voltage for protective separation / in networks with grounded star point between main and auxiliary circuit | 400 V |
| General technical data / protection class IP / on the front according to IEC 60529 | IP20 |
| General technical data / protection class IP / on the front | IP20 |
| General technical data / protection class IP / of the terminal | IP20 |
| General technical data / shock resistance according to IEC 60068-2-27 | 25g / 11 ms |
| General technical data / mechanical service life (operating cycles) / of the main contacts typical | 100 000 |
| General technical data / mechanical service life (operating cycles) / of auxiliary contacts typical | 100 000 |
| General technical data / electrical endurance (operating cycles) typical | 100 000 |
| General technical data / reference code according to IEC 81346-2 | Q |
| General technical data / continuous current rated value | 16 A |
| General technical data / Substance Prohibitance (day/month/year) | 10/01/2009 |
| General technical data / Net Weight | 338.6 g |
| Ambient conditions / installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature / during operation | -20 ... +60 °C |
| ambient temperature / during storage | -50 ... +80 °C |
| ambient temperature / during transport | -50 ... +80 °C |
| temperature compensation | -20 ... +60 °C |
| relative humidity during operation | 10 ... 95 % |
| Main circuit / number of poles for main current circuit | 3 |
| Main circuit / adjustable current response value current of the current- dependent overload release | 10 ... 16 A |
| Main circuit / type of voltage for main current circuit | AC |
| Main circuit / operating voltage / rated value | 690 V; 20 ... 690 V |
| Main circuit / operating voltage / at AC-3 rated value maximum | 690 V |
| Main circuit / operating voltage / at AC-3e rated value maximum | 690 V |
| Main circuit / operating frequency rated value | 50 ... 60 Hz |
| Main circuit / operational current rated value | 16 A |
| Main circuit / operational current / at AC-3 at 400 V rated value | 16 A |
| Main circuit / operational current / at AC-3e at 400 V rated value | 16 A |
| operating power / at AC-3 / at 230 V rated value | 4 kW |
| operating power / at AC-3 / at 400 V rated value | 7.5 kW |
| operating power / at AC-3 / at 500 V rated value | 7.5 kW |
| operating power / at AC-3 / at 690 V rated value | 11 kW |
| operating power / at AC-3e / at 230 V rated value | 4 kW |
| operating power / at AC-3e / at 400 V rated value | 7.5 kW |
| operating power / at AC-3e / at 500 V rated value | 7.5 kW |
| operating power / at AC-3e / at 690 V rated value | 11 kW |
| Main circuit / operating frequency / at AC-3 maximum | 15 1/h |
| Main circuit / operating frequency / at AC-3e maximum | 15 1/h |
| Auxiliary circuit / type of voltage for auxiliary and control circuit | AC/DC |
| Auxiliary circuit / number of NC contacts for auxiliary contacts | 0 |
| Auxiliary circuit / number of NO contacts for auxiliary contacts | 0 |
| Auxiliary circuit / number of CO contacts for auxiliary contacts | 0 |
| Protective and monitoring functions / product function / ground fault detection | No |
| Protective and monitoring functions / product function / phase failure detection | Yes |
| Protective and monitoring functions / trip class | CLASS 10 |
| Protective and monitoring functions / design of the overload release | thermal |
| Protective and monitoring functions / protection function thermal overload protection (ANSI 49) | Yes |
| Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 240 V rated value | 100 kA |
| Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 400 V rated value | 55 kA |
| Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 500 V rated value | 10 kA |
| Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 690 V rated value | 4 kA |
| Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 240 V rated value | 100 kA |
| Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 400 V rated value | 25 kA |
| Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 500 V rated value | 5 kA |
| Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 690 V rated value | 2 kA |
| Protective and monitoring functions / response value current of instantaneous short-circuit trip unit | 208 A |
| full-load current (FLA) for 3-phase AC motor / at 480 V rated value | 16 A |
| full-load current (FLA) for 3-phase AC motor / at 600 V rated value | 16 A |
| yielded mechanical performance [hp] / for single-phase AC motor / at 110/120 V rated value | 1 hp |
| yielded mechanical performance [hp] / for single-phase AC motor / at 230 V rated value | 2 hp |
| yielded mechanical performance [hp] / for 3-phase AC motor / at 200/208 V rated value | 3 hp |
| yielded mechanical performance [hp] / for 3-phase AC motor / at 220/230 V rated value | 5 hp |
| yielded mechanical performance [hp] / for 3-phase AC motor / at 460/480 V rated value | 10 hp |
| UL File Number (CCN) | E47705 (NLRV, NLRV7), E156943 (NKJH, NKJH7) |
| Short-circuit protection / product function short circuit protection | Yes |
| Short-circuit protection / design of the short-circuit trip | magnetic |
| Short-circuit protection / protection of the main circuit / at 400 V | gL/gG 63 A |
| Short-circuit protection / protection of the main circuit / at 500 V | gL/gG 50 A |
| Short-circuit protection / protection of the main circuit / at 690 V | gL/gG 40 A |
| Short-circuit protection / type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD |
| Installation/ mounting/ dimensions / mounting position | any |
| Installation/ mounting/ dimensions / fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| Installation/ mounting/ dimensions / Mounting method of circuit breaker for Transformer protection, Generator protection and system protection optional standard bar mounting | Yes |
| Installation/ mounting/ dimensions / height | 97 mm |
| Installation/ mounting/ dimensions / width | 45 mm |
| Installation/ mounting/ dimensions / depth | 97 mm |
| required spacing / with side-by-side mounting / forwards | 0 mm |
| required spacing / with side-by-side mounting / backwards | 0 mm |
| required spacing / with side-by-side mounting / upwards | 50 mm |
| required spacing / with side-by-side mounting / downwards | 50 mm |
| required spacing / with side-by-side mounting / at the side | 0 mm |
| required spacing / for grounded parts / forwards | 0 mm |
| required spacing / for grounded parts / backwards | 0 mm |
| required spacing / for grounded parts / upwards | 50 mm |
| required spacing / for grounded parts / at the side | 30 mm |
品番: 3RA2816-0EW20
品番: 3RT2035-1NB30
品番: 6MF2805-0AA00
品番: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.