品番
ATV610U15N4-1.5kW 3p 380-460 Vac
単位
Cái
供給状況
Liên hệ báo giá
必要数量 (Cái)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã hàng | ATV610U15N4-1.5kW 3p 380-460 Vac |
| Range of product | Altivar ATV610 |
| Hãng sản xuất | Schneider Electric |
| Product specific application | Fan, pump, compressor, conveyor |
| Nhóm sản phẩm | Biến tần |
| Product or component type | Variable speed drive |
| Danh mục | Biến tần |
| Device short name | ATV610 |
| Model / mã đặt hàng | ATV610U15N4-1.5kW 3p 380-460 Vac |
| Variant | Standard version |
| Điện áp | 460 V |
| Product destination | Asynchronous motors<br />Synchronous motors |
| Công suất | 1.5 kW |
| Mounting mode | Cabinet mount |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| Số cực | 3P |
| Chức năng | Điều khiển tốc độ động cơ |
| IP degree of protection | IP20 |
| Type of cooling | Forced convection |
| Ứng dụng | Tủ điện, hệ thống phân phối điện, tự động hóa và MRO nhà máy |
| Đối chiếu trước khi mua | Kiểm tra mã đặt hàng, dòng/áp, số cực, option và ảnh nhãn thiết bị đang dùng |
| Supply frequency | 50...60 Hz +/-5 % |
| Network number of phases | 3 phases |
| Nguồn dữ liệu | CRM TESFA; ảnh theo mã/series/nhóm Schneider để hỗ trợ nhận diện ban đầu |
| [Us] rated supply voltage | 380...460 V - 15...10 % |
| Motor power kW | 1.5 kW for normal duty<br />0.75 kW for heavy duty |
| Motor power hp | 2 hp for normal duty<br />1 hp for heavy duty |
| Line current | 5.7 A at 380 V (normal duty)<br />4.8 A at 460 V (normal duty)<br />3.1 A at 380 V (heavy duty)<br />2.6 A at 460 V (heavy duty) |
| Prospective line Isc | 5 kA |
| Apparent power | 3.8 kVA at 460 V (normal duty)<br />2.1 kVA at 460 V (heavy duty) |
| Continuous output current | 4 A at 4 kHz for normal duty<br />2.2 A at 4 kHz for heavy duty |
| Maximum transient current | 4.4 A during 60 s (normal duty)<br />3.3 A during 60 s (heavy duty) |
| Asynchronous motor control profile | Optimized torque mode<br />Constant torque standard<br />Variable torque standard |
| Output frequency | 0.1…500 Hz |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2...12 kHz adjustable |
| number of preset speeds | 16 preset speeds |
| Communication port protocol | Modbus serial |
| Option card | Slot A: communication card, Profibus DP V1<br />Slot A: digital or analog I/O extension card<br />Slot A: relay output card |
| Output voltage | <= power supply voltage |
| Motor slip compensation | Adjustable<br />Automatic whatever the load<br />Not available in permanent magnet motor law<br />Can be suppressed |
| Acceleration and deceleration ramps | S, U or customized<br />Linear adjustable separately from 0.01 to 9000 s |
| Braking to standstill | By DC injection |
| Protection type | Thermal protection: motor<br />Motor phase break: motor<br />Thermal protection: drive<br />Overheating: drive<br />Overcurrent between output phases and earth: drive<br />Overload of output voltage: drive<br />Short-circuit protection: drive<br />Motor phase break: drive<br />Overvoltages on the DC bus: drive<br />Line supply overvoltage: drive<br />Line supply undervoltage: drive<br />Line supply phase loss: drive<br />Overspeed: drive<br />Break on the control circuit: drive |
| Frequency resolution | Display unit: 0.1 Hz<br />Analog input: 0.012/50 Hz |
| Electrical connection | Control, screw terminal: 0.5...1.5 mm²<br />Line side, screw terminal: 2.5...16 mm²<br />Motor, screw terminal: 2.5...16 mm² |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Transmission frame | RTU for Modbus serial |
| Transmission rate | 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Type of polarization | No impedance for Modbus serial |
| Number of addresses | 1…247 for Modbus serial |
| Method of access | Slave |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection<br />Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Local signalling | 2 LEDs for local diagnostic<br />1 LED (yellow) for embedded communication status<br />2 LEDs (dual colour) for communication module status<br />1 LED (red) for presence of voltage |
| Width | 145 mm |
| Depth | 203 mm |
| Net weight | 3.135 kg |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits<br />AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits<br />AI2, AI3 software-configurable temperature probe or water level sensor |
| Discrete input number | 6 |
| Discrete input type | DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm<br />DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Input compatibility | DI1...DI6: logic input level 1 PLC conforming to IEC 61131-2<br />DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 |
| Discrete input logic | Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)<br />Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)<br />Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Analogue output number | 2 |
| Analogue output type | Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits<br />Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input<br />2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input<br />5 ms +/- 1 ms (DI5, DI6)configurable - pulse input<br />10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input<br />+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input<br />AQ1, AQ2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles<br />Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles<br />Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |