Khởi động từ ABB AF116-30-11-13. Product Net Width: 90 mm; Product Net Depth / Length: 126 mm.
品番
AF116-30-11-13
単位
Chưa cập nhật
供給状況
Liên hệ báo giá
必要数量 (Chưa cập nhật)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | AF116-30-11-13 |
| Mã định danh ABB | 1SFL427001R1311 |
| Model ABB | AF116-30-11-13 |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.55 kg |
| Dimension Diagram | 1SFB535001G1051 |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 160 A; (690 V) 60 °C 145 A; (690 V) 70 °C 130 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 60 °C 116 A; (440 V) 60 °C 116 A; (500 V) 60 °C 110 A; (690 V) 60 °C 65 A; (380 / 400 V) 60 °C 116 A; (220 / 230 / 240 V) 60 °C 116 A |
| Rated Operational Current AC-3e (I e ) | (415 V) 60 °C 116 A; (440 V) 60 °C 116 A; (500 V) 60 °C 110 A; (690 V) 60 °C 65 A; (380 / 400 V) 60 °C 116 A; (220 / 230 / 240 V) 60 °C 116 A |
| Rated Operational Current DC-1 (I e ) | (110 V) 2 Poles in Series, 40 °C 145 A; (220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Current DC-3 (I e ) | (110 V) 2 Poles in Series, 40 °C 145 A; (220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Current DC-5 (I e ) | (110 V) 2 Poles in Series, 40 °C 145 A; (220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Power AC-3 (P e ) | (415 V) 55 kW; (440 V) 75 kW; (500 V) 75 kW; (690 V) 55 kW; (380 / 400 V) 55 kW; (220 / 230 / 240 V) 30 kW |
| Rated Operational Power AC-3e (P e ) | (415 V) 55 kW; (440 V) 75 kW; (500 V) 75 kW; (690 V) 55 kW; (380 / 400 V) 55 kW; (220 / 230 / 240 V) 30 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 250 A |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A; cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour; (AC-2 / AC-4) 150 cycles per hour; (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U c ) | 50 Hz 100 ... 250 V; 60 Hz 100 ... 250 V; DC Operation 100 ... 250 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 32.2 V·A; Holding at Max. Rated Control Circuit Voltage 50 Hz 2.8 W; Holding at Max. Rated Control Circuit Voltage 60 Hz 32.2 V·A; Holding at Max. Rated Control Circuit Voltage 60 Hz 2.8 W; Holding at Max. Rated Control Circuit Voltage DC 2.9 W; Pull-in at Max. Rated Control Circuit Voltage 50 Hz 242 V·A; Pull-in at Max. Rated Control Circuit Voltage 60 Hz 242 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 289 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 289 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W; at Rated Operating Conditions AC-3 per Pole 2 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms; Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 10 ... 70 mm²; Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²; Flexible 2x0.75 ... 2.5 mm²; Solid 2 x 1 ... 4 mm²; Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 10 ... 70 mm²; Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque | Cable Lug 9 N·m; Main Circuit 8 N·m |
| Terminal Type | Double Clamp |
| Product Name | Block Contactor |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 160 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 30 hp; (208 V AC) Three Phase 30 hp; (220 ... 240 V AC) Three Phase 40; (440 ... 480 V AC) Three Phase 75 hp; (550 ... 600 V AC) Three Phase 100 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 96 A; (550 ... 600 V AC) Three Phase 99 A |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C; Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C; Close to Contactor for Storage -40 ... 70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
品番: ACS880-01-293A-3
品番: ACS880-01-032A-3
品番: ACS880-01-072A-3
品番: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.