品番: XB5AA31
- 単位
- Cái
コンテンツを読み込み中…
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。

Contactor/khởi động từ Schneider LC1D32M7 32 A. TESFA hỗ trợ đối chiếu mã, thông số điện và báo giá cho nhu cầu MRO công nghiệp.
品番
LC1D32M7 32 A
単位
Cái
供給状況
Liên hệ báo giá
必要数量 (Cái)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã hàng | LC1D32M7 32 A |
| Range of product | TeSys Deca Advanced |
| Hãng sản xuất | Schneider Electric |
| Product or component type | Contactor |
| Device short name | LC1D |
| Nhóm sản phẩm | Contactor/khởi động từ |
| Contactor application | Resistive load<br />Motor control |
| Danh mục | Contactor |
| Model / mã đặt hàng | LC1D32M7 32 A |
| Utilisation category | AC-3<br />AC-3e<br />AC-1<br />AC-4 |
| Dòng định mức | 32 A |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz<br />Power circuit: <= 300 V DC |
| Ứng dụng | Tủ điện, hệ thống phân phối điện, tự động hóa và MRO nhà máy |
| Đối chiếu trước khi mua | Kiểm tra mã đặt hàng, dòng/áp, số cực, option và ảnh nhãn thiết bị đang dùng |
| [Ie] rated operational current | 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit<br />50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit<br />32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Nguồn dữ liệu | CRM TESFA; ảnh theo mã/series/nhóm Schneider để hỗ trợ nhận diện ban đầu |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Motor power kW | 7.5 kW at 220/230 V AC 50/60 Hz (AC-3)<br />15 kW at 380/400 V AC 50/60 Hz (AC-3)<br />15 kW at 415/440 V AC 50/60 Hz (AC-3)<br />18.5 kW at 500 V AC 50/60 Hz (AC-3)<br />18.5 kW at 660/690 V AC 50/60 Hz (AC-3)<br />7.5 kW at 220/230 V AC 50/60 Hz (AC-3e)<br />15 kW at 380/400 V AC 50/60 Hz (AC-3e)<br />15 kW at 415/440 V AC 50/60 Hz (AC-3e)<br />18.5 kW at 500 V AC 50/60 Hz (AC-3e)<br />18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)<br />7.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 2 hp at 115 V AC 50/60 Hz for 1 phase motors<br />5 hp at 230/240 V AC 50/60 Hz for 1 phase motors<br />10 hp at 200/208 V AC 50/60 Hz for 3 phases motors<br />10 hp at 230/240 V AC 50/60 Hz for 3 phases motors<br />20 hp at 460/480 V AC 50/60 Hz for 3 phases motors<br />25 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit<br />50 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1<br />550 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 550 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit<br />430 A 40 °C - 1 s for power circuit<br />60 A 40 °C - 10 min for power circuit<br />138 A 40 °C - 1 min for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1<br />63 A gG at <= 690 V coordination type 1 for power circuit<br />63 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2 mOhm - Ith 50 A 50 Hz for power circuit |
| Power dissipation per pole | 2 W AC-3<br />5 W AC-1<br />2 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1<br />Power circuit: 600 V CSA certified<br />Power circuit: 600 V UL certified<br />Signalling circuit: 690 V conforming to IEC 60947-1<br />Signalling circuit: 600 V CSA certified<br />Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V<br />1.4 Mcycles 50 A AC-1 at Ue <= 440 V<br />1.65 Mcycles 32 A AC-3e at Ue <= 440 V |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz<br />0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz<br />0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz<br />1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C)<br />70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)<br />7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing<br />4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end<br />Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end<br />Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end<br />Power circuit: screw clamp terminals 1 1…10 mm² - cable stiffness: flexible with cable end<br />Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible with cable end<br />Power circuit: screw clamp terminals 1 1.5…10 mm² - cable stiffness: solid without cable end<br />Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm<br />Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2<br />Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm<br />Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2<br />Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2<br />Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1<br /> type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate<br />Rail |
| Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 60947-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ<br />CSA C22.2 No 60947-4-1 |
| Product certifications | UL<br />CCC<br />CSA<br />Marine<br />UKCA<br />EAC<br />CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat<br /> conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C<br />60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) <br />Vibrations contactor closed (4 Gn, 5...300 Hz) <br />Shocks contactor closed (15 Gn for 11 ms) <br />Shocks contactor open (8 Gn for 11 ms) |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 92 mm |
| Net weight | 0.375 kg |