品番: ACS880-01-293A-3
- 単位
- Chưa cập nhật
コンテンツを読み込み中…
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。

Rơ le quá tải điện tử ABB 1SAX351001R1101. Product Net Width: 89.05 mm; Product Net Height: 150.4 mm.
品番
1SAX351001R1101
単位
Chưa cập nhật
供給状況
見積はお問い合わせください
必要数量 (Chưa cập nhật)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | 1SAX351001R1101 |
| Mã định danh ABB | 1SAX351001R1101 |
| Model ABB | EF146-150 |
| Product Net Width | 89.05 mm |
| Product Net Height | 150.4 mm |
| Product Net Depth / Length | 105.2 mm |
| Product Net Weight | 0.879 kg |
| Setting Range | 54 ... 150 A |
| Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC; Main Circuit 1000 V AC |
| Rated Operational Current (I e ) | 150 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz; Auxiliary Circuit 60 Hz; Auxiliary Circuit DC; Main Circuit 50 Hz; Main Circuit 60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV; Main Circuit 8 kV |
| Rated Insulation Voltage (U i ) | 1000 V |
| Number of Poles | 3P |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Auxiliary Circuit NC 6 A; Auxiliary Circuit NO 6 A |
| Rated Operational Current AC-15 (I e ) | (240 V) NC 3 A; (240 V) NO 3 A; (400 V) NC 1.1 A; (400 V) NO 1.1 A; (500 V) NC 0.75 A; (500 V) NO 0.75 A |
| Rated Operational Current DC-13 (I e ) | (125 V) NC 0.55 A; (125 V) NO 0.5 A; (24 V) NC 1.5 A; (24 V) NO 1.5 A; (250 V) NC 0.27 A; (250 V) NO 0.27 A; (60 V) NC 0.55 A; (60 V) NO 0.55 A |
| Degree of Protection | Housing IP20; Main Circuit Terminals IP10 |
| Pollution Degree | 3 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²; Flexible 1/2x 0.75 ... 2.5 mm²; Rigid 1/2x 1 ... 4 mm² |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 10 ... 70 mm²; Flexible with Ferrule 2x 10 ... 35 mm²; Flexible with Insulated Ferrule 1x 10 ... 70 mm²; Flexible with Insulated Ferrule 2x 2 ... 35 mm²; Flexible 1x 10 ... 70 mm²; Flexible 2x 10 ... 35 mm²; Rigid 1x 10 ... 95 mm²; Rigid 2x 10 ... 35 mm² |
| Tightening Torque | Auxiliary Circuit 0.8 ... 1.2 N·m; Main Circuit 10 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm; Main Circuit 20 mm |
| Recommended Screw Driver | Auxiliary Circuit Pozidriv 2; Main Circuit Hexagon 4 |
| Mounting Position | 1 ... 6 |
| Power Loss | at Rated Operating Conditions per Pole 1.575 W |
| Suitable For | AF116; AF140; AF146 |
| Standards | IEC/EN 60947-1; IEC/EN 60947-4-1; IEC/EN 60947-5-1; UL 60947-1; UL 60947-4-1 |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NC:) B600; (NC:) Q600; (NO:) B600; (NO:) Q600 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1x 6-00 AWG; Flexible 2x 6-2 AWG; Stranded 2x 6-2 AWG; Stranded 1x 6-00 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-10 AWG; Stranded 1/2x 18-10 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 7 ... 1 in·lb; Main Circuit 70 in·lb |
| Ambient Air Temperature | Operation -25 ... +70 °C; Operation Compensated -25 ... +70 °C; Storage -50 ... +85 °C |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
品番: ACS880-01-293A-3
品番: ACS880-01-032A-3
品番: ACS880-01-072A-3
品番: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.