物料编码: ACS880-01-293A-3
- 单位
- Chưa cập nhật
正在加载内容…
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。

Khởi động từ ABB 1SFL447001R1311. Product Net Width: 90 mm; Product Net Depth / Length: 126 mm.
物料编码
1SFL447001R1311
单位
Chưa cập nhật
供货状态
Liên hệ báo giá
需求数量 (Chưa cập nhật)
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。
| 属性 | 产品规格 |
|---|---|
| Mã sản phẩm | 1SFL447001R1311 |
| Mã định danh ABB | 1SFL447001R1311 |
| Model ABB | AF140-30-11-13 |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.55 kg |
| Dimension Diagram | 1SFB535001G1051 |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 200 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 200 A; (690 V) 70 °C 160 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 55 °C 140 A; (440 V) 55 °C 140 A; (500 V) 55 °C 130 A; (690 V) 55 °C 80 A; (380 / 400 V) 55 °C 140 A; (220 / 230 / 240 V) 55 °C 140 A |
| Rated Operational Current AC-3e (I e ) | (415 V) 60 °C 140 A; (440 V) 60 °C 140 A; (500 V) 60 °C 130 A; (690 V) 60 °C 80 A; (380 / 400 V) 60 °C 140 A; (220 / 230 / 240 V) 60 °C 140 A |
| Rated Operational Current DC-1 (I e ) | (110 V) 2 Poles in Series, 40 °C 160 A; (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (I e ) | (110 V) 2 Poles in Series, 40 °C 160 A; (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (I e ) | (110 V) 2 Poles in Series, 40 °C 160 A; (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Power AC-3 (P e ) | (415 V) 75 kW; (440 V) 90 kW; (500 V) 90 kW; (690 V) 75 kW; (380 / 400 V) 75 kW; (220 / 230 / 240 V) 37 kW |
| Rated Operational Power AC-3e (P e ) | (415 V) 75 kW; (440 V) 90 kW; (500 V) 90 kW; (690 V) 75 kW; (380 / 400 V) 75 kW; (220 / 230 / 240 V) 37 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 315 A |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A; cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour; (AC-2 / AC-4) 150 cycles per hour; (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U c ) | 50 Hz 100 ... 250 V; 60 Hz 100 ... 250 V; DC Operation 100 ... 250 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 32.2 V·A; Holding at Max. Rated Control Circuit Voltage 50 Hz 2.8 W; Holding at Max. Rated Control Circuit Voltage 60 Hz 32.2 V·A; Holding at Max. Rated Control Circuit Voltage 60 Hz 2.8 W; Holding at Max. Rated Control Circuit Voltage DC 2.9 W; Pull-in at Max. Rated Control Circuit Voltage 50 Hz 242 V·A; Pull-in at Max. Rated Control Circuit Voltage 60 Hz 242 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 289 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 289 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 5 W; at Rated Operating Conditions AC-3 per Pole 3 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms; Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 10 ... 70 mm²; Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²; Flexible 2x0.75 ... 2.5 mm²; Solid 2 x 1 ... 4 mm²; Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 1 x 10 ... 70 mm²; Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque | Cable Lug 9 N·m; Main Circuit 8 N·m |
| Terminal Type | Double Clamp |
| Product Name | Block Contactor |
| NEMA Size | 4 |
| Continuous Current Rating NEMA | 135 A |
| Horsepower Rating NEMA | (200 V AC) Three Phase 40 Hp; (230 V AC) Three Phase 50 Hp; (460 V AC) Three Phase 100 Hp; (575 V AC) Three Phase 100 Hp |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 200 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 40 hp; (208 V AC) Three Phase 40 hp; (220 ... 240 V AC) Three Phase 50; (440 ... 480 V AC) Three Phase 100 hp; (550 ... 600 V AC) Three Phase 125 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 124 A; (550 ... 600 V AC) Three Phase 125 A |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C; Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C; Close to Contactor for Storage -40 ... 70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
物料编码: ACS880-01-293A-3
物料编码: ACS880-01-032A-3
物料编码: ACS880-01-072A-3
物料编码: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.