Aptomat tép ABB 2CDS272061R0064. Number of Poles: 2P; Rated Insulation Voltage (U i ): acc. to IEC/EN 60664-1 440 V.
物料编码
2CDS272061R0064
单位
Chưa cập nhật
供货状态
联系报价
需求数量 (Chưa cập nhật)
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。
| 属性 | 产品规格 |
|---|---|
| Mã sản phẩm | 2CDS272061R0064 |
| Mã định danh ABB | 2CDS272061R0064 |
| Model ABB | S202M-C6UC |
| Dielectric Test Voltage | 50 / 60 Hz - 1 min 2 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | (220 V DC) 25 kA; (230 V AC) 15 kA; (400 V AC) 15 kA; (440 V AC) 10 kA; (440 V DC) 10 kA; (230 V) 10 kA |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | (220 V DC) 20 kA |
| Power Supply Connection | Please Note Polarity of Device |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 20000 AC cycle |
| Mechanical Endurance | 20000 cycle |
| Number of Protected Poles | 2 |
| Number of Poles | 2P |
| Tightening Torque | 2.8 N·m |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Actuator Marking | I / O |
| Actuator Material | Insulation Group II, Black, Sealable |
| Options Provided | Universal current |
| Recommended Screw Driver | Pozidriv 2 |
| Remarks | Please note polarity of device |
| Connecting Capacity | Busbar 10/10 mm²; Flexible with Ferrule 0.75 ... 25 mm²; Flexible 0.75 ... 25 mm²; Rigid 0.75 ... 35 mm²; Stranded 0.75 ... 35 mm² |
| Installation Size | acc. to DIN 43880 1 |
| Terminal Type | Screw Terminals |
| Actuator Type | Toggle |
| Tripping Characteristic | C |
| Rated Operational Voltage | acc. to IEC 60898-1 400 V AC; acc. to IEC 60898-1 440 V DC; acc. to IEC 60898-2 400 V AC; acc. to IEC 60898-2 440 V DC; acc. to IEC 60947-2 440 V AC; acc. to IEC 60947-2 440 V DC |
| Operational Voltage | Maximum (Incl. Tolerance) 440 V AC; Maximum (Incl. Tolerance) 500 V DC; Minimum 12 V AC; Minimum 12 V DC |
| Rated Insulation Voltage (U i ) | acc. to IEC/EN 60664-1 440 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV; at 2000 m 5 kV; at Sea Level 6.2 kV |
| Input Voltage Type | AC/DC |
| Rated Current (I n ) | 6 A |
| Rated Short-Circuit Capacity | (AC) 10 kA; (230 V AC) 10 kA; (253 V AC) 10 kA; (400 V AC) 10 kA; (440 V DC) 10 kA; (230 V) 10 kA; (400 V) 10 kA |
| Rated Frequency (f) | 50 / 60 Hz; DC |
| Power Loss | 4 W; at Rated Operating Conditions per Pole 2 W |
| Overvoltage Category | III |
| Housing Material | Insulation Group I, RAL 7035 |
| Maximum Operating Voltage UL/CSA | 480Y/277 V AC; 500 V DC |
| Interrupting Rating acc. to UL1077 | (220 V AC) 10 kA; (277 V AC) 6 kA; (440 V DC) 10 kA; (480Y / 277 V AC) 10 kA; (500 V DC) 10 kA |
| Connecting Capacity UL/CSA | Busbar 14-8 AWG; Conductor 14-4 AWG |
| Tightening Torque UL/CSA | 25 in·lb |
| Ambient Air Temperature | Operation -25 ... +55 °C; Storage -40 ... +70 °C |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20; Enclosure with Cover IP40 |
| Pollution Degree | 3 |
| Environmental Conditions | 28 cycles; with 55 °C / 90-96 %; and 25 °C / 95-100 % |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm |
| Product Net Height | 88 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 0.234 kg |
| Pole Net Weight | 0.125 kg |
| Built-In Depth ( t 2 ) | 69 mm |
| Instructions and Manuals | 2CDS207104P0002 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715; TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Mounting Position | any |
物料编码: ACS880-01-293A-3
物料编码: ACS880-01-032A-3
物料编码: ACS880-01-072A-3
物料编码: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.