物料编码: 060-110191
- 单位
- Cái
正在加载内容…
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。

Cảm biến áp suất IFM PN2071. Number of inputs and outputs: Number of digital outputs: 2; Number of analog outputs: 1; Measuring range: 0...250 bar: 0...3625 psi: 0...25 MPa.
物料编码
PN2071
单位
Cái
供货状态
Liên hệ báo giá
需求数量 (Cái)
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。
| 属性 | 产品规格 |
|---|---|
| Mã sản phẩm | PN2071 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | 0...250 bar: 0...3625 psi: 0...25 MPa |
| Process connection | threaded connection G 1/4 Internal thread (DIN EN ISO 1179-2) |
| Special feature | gold-plated contacts |
| Measuring element | metallic thin film cell |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature [°C] | -25...80 |
| Min. burst pressure | 1200 bar: 17400 psi: 120 MPa |
| Pressure rating | 500 bar: 7250 psi: 50 MPa |
| Vacuum resistance | -1000 mbar: -0.1 MPa |
| Type of pressure | relative pressure |
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | < 35 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.3 |
| Integrated watchdog | yes |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 500 |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (scalable 1:5) |
| Max. load [Ω] | 500 |
| Analog voltage output [V] | 0...10; (scalable 1:5) |
| Min. load resistance [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Analog start point | 0...200 bar: 0...2900 psi: 0...20 MPa |
| Analog end point | 50...250 bar: 725...3625 psi: 5...25 MPa |
| Set point SP | 1.5...250 bar: 25...3625 psi: 0.15...25 MPa; 1.6...250 bar: 23...3626 psi: 0.16...25 MPa |
| Reset point rP | 0.5...249 bar: 10...3610 psi: 0.05...24.9 MPa; 0.5...249 bar: 8...3611 psi: 0.05...24.9 MPa |
| Min. difference between SP and rP | 1.5 bar: 15 psi: 0.15 MPa; 1.1 bar: 15 psi: 0.11 MPa |
| In steps of | 0.5 bar: 5 psi: 0.05 MPa; 0.1 bar: 1 psi: 0.01 MPa |
| Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-25...80 °C) |
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-25...80 °C) |
| Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |
| Response time [ms] | < 1.5 |
| Delay time programmable dS, dr [s] | 0...50 |
| Damping process value dAP [s] | 0...4 |
| Damping for the analog output dAA [s] | 0...4 |
| Max. response time analog output [ms] | 3 |
| Parameter setting options | hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| SIO mode | yes |
| Required master port class | A; (when pin 2 not connected: B) |
| Supported DeviceIDs | Type of operation: DeviceID; Factory setting / CMPT = 2: 460; Status_B High Resolution / CMPT = 3: 639 |
| Note | For further information please see the IODD PDF file at "Downloads" |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis; Smart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis |
| Min. process cycle time [ms] | 2.3; 3 |
| IO-Link resolution pressure [bar] | 0.1 |
| IO-Link process data (cyclical) | Function: bit length; pressure: 14; binary switching information: 2; Function: bit length; pressure: 16; device status: 4; binary switching information: 2 |
| IO-Link functions (acyclical) | application specific tag |
| Ambient temperature [°C] | -25...80 |
| Storage temperature [°C] | -40...100 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27: 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 20 g (10...2000 Hz) |
| MTTF [years] | 129 |
| UL approval | UL approval number: J014 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g] | 234.5 |
| Housing | tubular |
| Dimensions [mm] | Ø 34 / L = 90.7 |
| Material | stainless steel (630/1.4542/17-4 PH); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) | stainless steel (630/1.4542/17-4 PH) |
| Min. pressure cycles | 100 million |
| Tightening torque [Nm] | 25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating) |
| Restrictor element integrated | no (can be retrofitted) |
| Display | Display unit: 3 x LED, green (bar, psi, MPa); Switching status: 2 x LED, yellow; Measured values: alphanumeric display, red/green 4-digit |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
物料编码: 060-110191
物料编码: 060-117191
物料编码: IFS203
物料编码: EVT406
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.