物料编码: IFS203
- 单位
- Chưa cập nhật
正在加载内容…
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。

Cảm biến lưu lượng IFM SM8601. Number of inputs and outputs: Number of digital outputs: 2; Number of analog outputs: 1; Measuring range: 6...1584 gph: 0.1...26.4 gpm.
物料编码
SM8601
单位
Chưa cập nhật
供货状态
联系报价
需求数量 (Chưa cập nhật)
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。
| 属性 | 产品规格 |
|---|---|
| Mã sản phẩm | SM8601 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | 6...1584 gph: 0.1...26.4 gpm |
| Process connection | threaded connection 1" NPT Internal thread DN25 |
| Special feature | gold-plated contacts |
| Application | Totalizer function; for industrial applications |
| Media | Conductive liquids; water; water-based media |
| Note on media | conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C) |
| Medium temperature [°F] | 14...158 |
| Pressure rating | 16 bar: 232 psi: 1.6 MPa |
| MAWP (for applications according to CRN) | 10.4 bar: 1.04 MPa |
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | 95; (24 V) |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
| Measuring principle | magnetic-inductive |
| Inputs | counter reset |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 200 |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (scalable) |
| Max. load [Ω] | 500 |
| Analog voltage output [V] | 0...10; (scalable) |
| Min. load resistance [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Display range | -1902...1902 gph: -31.7...31.7 gpm |
| Resolution | 2 gph: 0.05 gpm |
| Set point SP | 14...1586 gph: 0.25...26.4 gpm |
| Reset point rP | 6...1578 gph: 0.1...26.25 gpm |
| Analog start point ASP | 0...1272 gph: 0...21.2 gpm |
| Analog end point AEP | 312...1586 gph: 5.2...26.4 gpm |
| In steps of | 2 gph: 0.05 gpm |
| Pulse value | 0.01...100 000 000 gal |
| Pulse length [s] | 0,0025...2 |
| Measuring range [°F] | -4...176 |
| Resolution [°F] | 0.5 |
| Set point SP [°F] | -2.5...176 |
| Reset point rP [°F] | -3.5...175 |
| Analog start point [°F] | -4...140.5 |
| Analog end point [°F] | 31.5...176 |
| In steps of [°F] | 0.5 |
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Accuracy [K] | ± 2,5 (Q > 0,26 gpm) |
| Response time [s] | 0.15; (dAP = 0, T19) |
| Delay time programmable dS, dr [s] | 0...50 |
| Damping process value dAP [s] | 0...5 |
| Dynamic response T05 / T09 [s] | T09 = 20 (Q > 0,26 gpm) |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 3 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 5 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 576 |
| Ambient temperature [°F] | 14...140 |
| Storage temperature [°F] | -13...176 |
| Protection | IP 67 |
| EMC | DIN EN 60947-5-9 |
| Shock resistance | DIN EN 60068-2-27: 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 145 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g] | 698.5 |
| Housing | tubular |
| Inlet pipe length | 3 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions [mm] | Ø 54 / L = 110 |
| Material | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
| Display | Display unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³); Switching status: 2 x LED, yellow; Measured values: alphanumeric display, 4-digit; Programming: alphanumeric display, 4-digit |
| Remarks | MW = Measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |