物料编码: QPL25.050
- 单位
- Cái
正在加载内容…
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。

Cáp công nghiệp SIEMENS 6XV1870-3QH30. product type designation: IE TP Cord RJ45/RJ45, 4x2; product description: Patch cable, preferred length, preassembled with two RJ45 connectors (10/100/1000/10000MB); product brand name: SIMATIC NET.
物料编码
6XV1870-3QH30
单位
Chưa cập nhật
供货状态
联系报价
需求数量 (Chưa cập nhật)
无需在线付款。TESFA 会核对物料代码、数量和供货条件,并根据您的联系方式回复报价。
对于 MRO 物料,确认正确型号比只看图片更重要。TESFA 会在确认报价前核对关键技术点。
| 属性 | 产品规格 |
|---|---|
| Mã sản phẩm | 6XV1870-3QH30 |
| Tên gọi chính hãng | Industrial Ethernet TP cord RJ45/RJ45, Cat6a, S/FTP cable 4x2, pre-assembled with 2 RJ45 connectors, length 3 m. |
| product type designation | IE TP Cord RJ45/RJ45, 4x2 |
| product description | Patch cable, preferred length, preassembled with two RJ45 connectors (10/100/1000/10000MB) |
| product brand name | SIMATIC NET |
| Technical Product Detail Page | https://i.siemens.com/1P6XV1870-3QH30 |
| suitability for use | Easy connection of terminal devices to the IE FC cabling system |
| cable designation | S/FTP, LI 02YSCH 4x2x0,15 PIMF GN FRNC |
| wire length | 3 m |
| electrical data / number of electrical connections | 2 |
| electrical data / attenuation factor per length / at 10 MHz / maximum | 0.086 dB/m |
| electrical data / attenuation factor per length / at 100 MHz / maximum | 0.28 dB/m |
| electrical data / attenuation factor per length / at 300 MHz / maximum | 0.501 dB/m |
| electrical data / attenuation factor per length / at 600 MHz / maximum | 0.735 dB/m |
| electrical data / impedance / at 1 MHz ... 100 MHz | 100 Ω |
| electrical data / impedance / at 10 MHz … 600 MHz | 100 Ω |
| electrical data / relative symmetrical tolerance / of the characteristic impedance at 1 MHz … 100 MHz | 15 % |
| electrical data / relative symmetrical tolerance / of the characteristic impedance at 10 MHz … 600 MHz | 10 % |
| electrical data / coupling loss / at 30 MHz … 100 MHz / minimum | 70 dB |
| electrical data / transfer impedance per length / at 10 MHz | 10 m Ω/ m |
| electrical data / loop resistance per length / maximum | 290 m Ω/ m |
| electrical data / operating voltage / RMS value | 80 V |
| electrical data / NVP value in percent | 80 % |
| mechanical data / number of electrical cores | 8 |
| mechanical data / design of the shield | S/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires |
| mechanical data / core diameter / of AWG26 insulated conductor | 0.5 mm |
| mechanical data / outer diameter / of inner conductor | 0.5 mm |
| mechanical data / outer diameter / of the wire insulation | 1 mm |
| mechanical data / outer diameter / of cable sheath | 6.2 mm |
| mechanical data / symmetrical tolerance of the outer diameter / of cable sheath | 0.3 mm |
| mechanical data / material / of the wire insulation | polyethylene (PE) |
| of cable sheath | FRNC |
| color / of the insulation of data wires | white/blue, white/orange, white/green, white/brown |
| color / of cable sheath | green |
| bending radius / with single bend / minimum permissible | 31 mm |
| bending radius / with multiple bends / minimum permissible | 43.5 mm |
| weight per length | 50 kg/km |
| plug / connector type | RJ45 |
| plug / type of plug interlock | latched |
| plug / design of plug-in connection | RJ45-180 |
| ambient conditions / ambient temperature / during operation | -25 ... +80 °C |
| ambient conditions / ambient temperature / during storage | -25 ... +80 °C |
| ambient conditions / ambient temperature / during transport | -25 ... +80 °C |
| ambient conditions / ambient temperature / during installation | -25 ... +80 °C |
| ambient conditions / ambient temperature / note | In fixed installation -40 °C to 80 °C |
| ambient conditions / fire behavior | flame resistant acc. to IEC 60332-1-2, EN 60332-3-24, smoke density acc. to IEC 61034 |
| ambient conditions / class of burning behaviour / according to EN 13501-6 | Eca |
| ambient conditions / chemical resistance / to mineral oil | oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
| ambient conditions / chemical resistance / to grease | Conditional resistance |
| ambient conditions / radiological resistance / to UV radiation | not resistant |
| ambient conditions / protection class IP | IP20 |
| product features, product functions, product components / general / product feature / halogen-free | Yes; halogen-free according to EN 60754-2 |
| product features, product functions, product components / general / product feature / PoE capability | Yes |
| product features, product functions, product components / general / product feature / PoE+ capability | Yes |
| product features, product functions, product components / general / product feature / PoE++ capability | Yes |
| product features, product functions, product components / general / product feature / silicon-free | Yes |
| product features, product functions, product components / general / test voltage / at AC / core-to-core | 500 V |
| product features, product functions, product components / general / test voltage / at AC / core shield | 1500 V |
| further information / internet links / internet link / to website: Selection guide for cables and connectors | https://support.industry.siemens.com/cs/ww/en/view/109766358 |
| further information / internet links / internet link / to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| further information / internet links / internet link / to web page: SiePortal | https://sieportal.siemens.com/ |
| further information / internet links / internet link / to website: Image database | https://www.automation.siemens.com/bilddb |
| to website: CAx-Download-Manager | https://www.siemens.com/cax |
| to website: Industry Online Support | https://support.industry.siemens.com |
| security information / security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |
物料编码: QPL25.050
物料编码: QPL25.500B
物料编码: SQM45.295B9
物料编码: 3RA2816-0EW20
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.