Module giao tiếp SIEMENS 6ES7153-1AA03-0XB0. General information / Tên kiểu sản phẩm: IM 153-1 DP ST; General information / Vendor identification (VendorID): 801Dh; Supply voltage / Rated value (DC): 24 V.
品番
6ES7153-1AA03-0XB0
単位
Chưa cập nhật
供給状況
Liên hệ báo giá
必要数量 (Chưa cập nhật)
オンライン決済は不要です。TESFA が品番、数量、供給条件を確認し、ご入力の連絡先へ見積を回答します。
MRO 品では、画像だけで選ぶより正しいコード確認が重要です。TESFA は見積確定前に主要な技術項目を確認します。
| 属性 | 製品仕様 |
|---|---|
| Mã sản phẩm | 6ES7153-1AA03-0XB0 |
| Tên gọi chính hãng | *** spare part *** SIMATIC DP, connection IM 153-1, for ET 200M, for max. 8 S7-300 modules |
| General information / Tên kiểu sản phẩm | IM 153-1 DP ST |
| General information / Vendor identification (VendorID) | 801Dh |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 20.4 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Supply voltage / external protection for power supply lines (recommendation) | not necessary |
| Supply voltage / Mains buffering / Mains/voltage failure stored energy time | 5 ms |
| Input current / Current consumption, max. | 350 mA; At 24 V DC |
| Input current / Inrush current, typ. | 2.5 A |
| Input current / I²t | 0.1 A²·s |
| Output voltage / Rated value (DC) | 5 V |
| Output current / for backplane bus (5 V DC), max. | 1 A |
| Power loss / Power loss, typ. | 3 W |
| Address area / Address space per module / Inputs | 128 byte |
| Address area / Address space per module / Outputs | 128 byte |
| Hardware configuration / number of modules per DP device interface, max. | 8 |
| Interfaces / Transmission procedure | RS 485 |
| Interfaces / Transmission rate, max. | 12 Mbit/s |
| 1. Interface / automatic detection of transmission rate | Yes |
| 1. Interface / Interface types / Output current of the interface, max. | 90 mA |
| 1. Interface / Interface types / Design of the connection | 9-pin sub D socket |
| 1. Interface / PROFIBUS DP device / GSD file | (for DPV1) SIEM801D.GSD; SI01801D.GSG |
| 1. Interface / PROFIBUS DP device / automatic baud rate search | Yes |
| Protocols / Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 |
| Protocols / Protocols (Ethernet) / TCP/IP | No |
| Protocols / PROFIBUS DP / Number of node addresses, max. | 1 to 125 permitted |
| PROFIBUS DP / Services / SYNC capability | Yes |
| PROFIBUS DP / Services / FREEZE capability | Yes |
| PROFIBUS DP / Services / Direct data exchange (slave-to-slave communication) | Yes; Sender |
| Potential separation / Potential separation exists | Yes |
| Isolation / Isolation tested with | Isolation voltage 500 V |
| Degree and class of protection / IP degree of protection | IP20 |
| Ambient conditions / Ambient temperature during operation / min. | 0 °C |
| Ambient conditions / Ambient temperature during operation / max. | 60 °C |
| Ambient conditions / Ambient temperature during operation / horizontal installation, min. | 0 °C |
| Ambient conditions / Ambient temperature during operation / horizontal installation, max. | 60 °C |
| Ambient conditions / Ambient temperature during operation / vertical installation, min. | 0 °C |
| Ambient conditions / Ambient temperature during operation / vertical installation, max. | 40 °C |
| Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max. | 3 000 m |
| Configuration / Configuration software / STEP 7 | STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file |
| Dimensions / Chiều rộng | 40 mm |
| Dimensions / Chiều cao | 125 mm |
| Dimensions / Chiều sâu | 117 mm |
| Weights / Khối lượng xấp xỉ | 360 g |
品番: QPL25.050
品番: QPL25.500B
品番: SQM45.295B9
品番: 3RA2816-0EW20
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.