AX25-30-10-80 220-230V50Hz/230-240V60Hz Contactor. Mã ABB 1SBL931074R8010; ảnh và thông số từ trang sản phẩm chính hãng.
Item code
1SBL931074R8010
Unit
Chưa cập nhật
Supply status
Liên hệ báo giá
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã đặt hàng | 1SBL931074R8010 |
| Extended Product Type | AX25-30-10-80 |
| Product ID | 1SBL931074R8010 |
| Catalog Description | AX25-30-10-80 220-230V50Hz/230-240V60Hz Contactor |
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 76.3 mm |
| Product Net Weight | 0.326 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V; Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz; Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A; acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (Ie) | (220 / 240 V) 55 °C 27 A; (690 V) 40 °C 32 A; (690 V) 70 °C 23 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 25 A; (440 V) 55 °C 16 A; (500 V) 55 °C 14 A; (690 V) 55 °C 10 A; (380 / 400 V) 55 °C 25 A; (220 / 230 / 240 V) 55 °C 25 A |
| Rated Operational Current AC-15 (Ie) | (500 V) NC 2; (500 V) 2 A; (690 V) 2 A; (24 / 127 V) 6 A; (220 / 240 V) 4 A; (380 / 400 V) 3 A; (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W; (110 V) 1.1 A / 121 W; (125 V) 1.1 A / 138 W; (220 V) 0.55 A / 121 W; (250 V) 0.55 A / 138 W; (400 V) 2.8 A / 134 W; (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (Pe) | (415 V) 11 kW; (440 V) 9 kW; (500 V) 9 kW; (690 V) 9 kW; (380 / 400 V) 11 kW; (220 / 230 / 240 V) 6.5 kW |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A; for 0.1 s 140 A; for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A; cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
Item code: ACS880-01-293A-3
Item code: ACS880-01-032A-3
Item code: ACS880-01-072A-3
Item code: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.