Bộ khởi động mềm ABB PSE250-600-70-1. Product Net Width: 190 mm; Product Net Height: 435 mm.
Item code
PSE250-600-70-1
Unit
Chưa cập nhật
Supply status
Liên hệ báo giá
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | PSE250-600-70-1 |
| Mã định danh ABB | 1SFA897113R7001 |
| Model ABB | PSE250-600-70-1 |
| Product Net Width | 190 mm |
| Product Net Height | 435 mm |
| Product Net Depth / Length | 237 mm |
| Product Net Weight | 10.6 kg |
| Rated Operational Voltage | 208 ... 600 V AC |
| Rated Control Supply Voltage (U s ) | 100 ... 250 V AC |
| Rated Control Circuit Voltage (U c ) | 24 V DC |
| Rated Frequency (f) | 50/60 Hz; Main Circuit 50 / 60 Hz |
| Rated Operational Power - In-Line Connection (Pe) | (230 V) 75 kW; (400 V) 132 kW; (500 V) 160 kW |
| Rated Operational Current - In-Line Connection (Ie) | 250 A |
| Service Factor Percentage | 100 % |
| Overload Protection | Built-in electronic overload protection |
| Integrated Electronic Overload | Yes |
| Starting Capacity at Maximum Rated Current Ie | 4xIe for 10s |
| Ramp Time | 0 ... 30 s; 1 ... 30 s |
| Initial Voltage During Start | 30 ... 70 % |
| Step Down Voltage Special Ramp | No % |
| Current Limit Function | 1.5 ... 7xIe |
| Switch for Inside Delta Connection | No |
| Run Signal Relay | Yes |
| By-pass Signal Relay | Yes |
| Fault Signal Relay | Yes |
| Overload Signal Relay | Yes |
| Analog Outputs | 4…20 mA |
| Signal Indication Completed Start Ramp (LED) | Green |
| Signal Indication Ready to Start/Standby ON (LED) | Green |
| Signal Indication Running R (LED) | Green |
| Signal Indication Ramping Up/Down (LED) | Green |
| Signal Indication Protection (LED) | Yellow |
| Signal Indication Fault (LED) | Red |
| Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time | 10 |
| Communication | Modbus-RTU |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Terminal Type | Main Circuit: Bars |
| Connecting Capacity Main Circuit | Hole Diameter 8.5 mm; Rigid 1/2 x 2.5 ... 70 mm²; Width and Thickness 17.5x5 mm |
| Connecting Capacity Control Circuit | Rigid 1 x 2.5 mm²; Rigid 2 x 1.5 mm² |
| Connecting Capacity Supply Circuit | Rigid 1 x 2.5 |
| Tightening Torque | Control Circuit 0.5 N·m; Main Circuit 28 N·m; Supply Circuit 0.5 N·m |
| Product Main Type | PSE250 |
| Function | Soft start with torque control; Soft start with voltage ramp; Soft stop with torque control; Soft stop with voltage ramp; Kick start; Sequence start; Current limit; Start reverse (external contactors); Automatic restart; Event log |
| Protection Function | Electronic overload protection, EOL; Locked rotor protection; Current underload protection |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 75 Hp; (220 ... 240 V AC) Three Phase 100 Hp; (440 ... 480 V AC) Three Phase 200 Hp; (550 ... 600 V AC) Three Phase 250 Hp |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| Tightening Torque UL/CSA | Control Circuit 4.4 in·lb; Main Circuit 247.8; Supply Circuit 4.4 in·lb |
| Ambient Air Temperature | Operation -25 ... +60 °C; Storage -40 ... +70 °C |
Item code: ACS880-01-293A-3
Item code: ACS880-01-032A-3
Item code: ACS880-01-072A-3
Item code: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.