Item code: ACS880-01-293A-3
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Khởi động từ ABB 1SFL617001R7011. Product Net Width: 210 mm; Product Net Depth / Length: 242 mm.
Item code
1SFL617001R7011
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 1SFL617001R7011 |
| Mã định danh ABB | 1SFL617001R7011 |
| Model ABB | AF580-30-11-70 |
| Product Net Width | 210 mm |
| Product Net Depth / Length | 242 mm |
| Product Net Height | 283 mm |
| Product Net Weight | 13.6 kg |
| Dimension Diagram | 53540919-60 |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A |
| Rated Operational Current AC-1 (I e ) | (1000 V) 40 °C 800 A; (1000 V) 55 °C 700 A; (1000 V) 70 °C 580 A; (690 V) 40 °C 800 A; (690 V) 55 °C 700 A; (690 V) 70 °C 580 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 55 °C 580 A; (440 V) 55 °C 580 A; (500 V) 55 °C 580 A; (690 V) 55 °C 500 A; (1000 V) 55 °C 250 A; (380 / 400 V) 55 °C 580 A; (220 / 230 / 240 V) 55 °C 580 A |
| Rated Operational Current DC-1 (I e ) | (110 V) 1-Pole, 40 °C 800 A; (110 V) 2 Poles in Series, 40 °C 800 A; (220 V) 3 Poles in Series, 40 °C 800 A; (600 V) 3 Poles in Series, 40 °C 800 A; (850 V) 3 Poles in Series, 40 °C 800 A |
| Rated Operational Current DC-3 (I e ) | (110 V) 1-Pole, 40 °C 800 A; (110 V) 2 Poles in Series, 40 °C 800 A; (220 V) 3 Poles in Series, 40 °C 800 A; (600 V) 3 Poles in Series, 40 °C 800 A |
| Rated Operational Current DC-5 (I e ) | (110 V) 1-Pole, 40 °C 800 A; (110 V) 2 Poles in Series, 40 °C 800 A; (220 V) 3 Poles in Series, 40 °C 800 A; (600 V) 3 Poles in Series, 40 °C 800 A |
| Rated Operational Power AC-3 (P e ) | (415 V) 355 kW; (440 V) 355 kW; (500 V) 400 kW; (690 V) 500 kW; (1000 V) 355 kW; (380 / 400 V) 315 kW; (220 / 230 / 240 V) 160 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 1000 A |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1300 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 4500 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 7000 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 6400 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3500 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A; cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour; (AC-2 / AC-4) 60 cycles per hour; (AC-3) 300 cycles per hour |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U c ) | 50 Hz 100 ... 250 V; 60 Hz 100 ... 250 V; DC Operation 100 ... 250 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 38.3 V·A; Holding at Max. Rated Control Circuit Voltage 50 Hz 4.6 W; Holding at Max. Rated Control Circuit Voltage 60 Hz 38.3 V·A; Holding at Max. Rated Control Circuit Voltage 60 Hz 4.6 W; Holding at Max. Rated Control Circuit Voltage DC 4.3 W; Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1229 V·A; Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1229 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 1292 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 1292 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 39 W; at Rated Operating Conditions AC-3 per Pole 21 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 50 ... 70 ms; Between Coil De-energization and NO Contact Opening 53 ... 73 ms; Between Coil Energization and NC Contact Opening 45 ... 115 ms; Between Coil Energization and NO Contact Closing 50 ... 120 ms |
| Connecting Capacity Main Circuit | Bar 52 mm²; Bar 50 mm²; Rigid Al-Cable 300 mm²; Rigid Al-Cable 3x185 mm²; Rigid Cu-Cable 300 mm²; Rigid Cu-Cable 3x185 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²; Flexible 2x0.75 ... 2.5 mm²; Solid 2 x 1 ... 4 mm²; Stranded 1 x 1 .... 4 mm²; Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Bar 52 mm²; Rigid Al-Cable 3x185 mm²; Rigid Cu-Cable 3x185 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Recommended Screw Driver | Main Circuit M12; Control Circuit Pozidriv 2; Control Circuit M3.5 |
| Tightening Torque | Cable Lug 45 N·m; Main Circuit 45 N·m |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 750 A; (600 V AC) 750 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 200 Hp; (200 V AC) Three Phase 200 hp; (208 V AC) Three Phase 200 hp; (220 ... 240 V AC) Three Phase 250 Hp; (220 ... 240 V AC) Three Phase 250; (440 ... 480 V AC) Three Phase 500 Hp; (440 ... 480 V AC) Three Phase 500 hp; (550 ... 600 V AC) Three Phase 600 Hp; (550 ... 600 V AC) Three Phase 600 hp |
| Full Load Amps Motor Use | (200 ... 208 V AC) Three Phase 552 A; (220 ... 240 V AC) Three Phase 604 A; (440 ... 480 V AC) Three Phase 590 A; (550 ... 600 V AC) Three Phase 578 A |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C; Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C; Close to Contactor for Storage -40 ... 70 °C; Operation -40 ... 70 °C; Storage -40 ... +70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g; Shock Direction: B1 5 g; Shock Direction: B2 5 g; Shock Direction: C1 5 g; Shock Direction: C2 5 g |
Item code: ACS880-01-293A-3
Item code: ACS880-01-032A-3
Item code: ACS880-01-072A-3
Item code: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.