Item code: 3RA2816-0EW20
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Khối tiếp điểm SIEMENS 3SU1400-1AA10-3EA0. product brand name: SIRIUS ACT; product designation: Contact module; product type designation: 3SU1.
Item code
3SU1400-1AA10-3EA0
Unit
Chưa cập nhật
Supply status
Liên hệ báo giá
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 3SU1400-1AA10-3EA0 |
| Tên gọi chính hãng | Contact module with 2 contact elements, 2 NC, spring-type terminal, for front plate mounting |
| product brand name | SIRIUS ACT |
| product designation | Contact module |
| product type designation | 3SU1 |
| Contact block/ lampholder / socket design | other |
| General technical data / product function positive opening | Yes |
| General technical data / insulation voltage rated value | 500 V |
| General technical data / degree of pollution | 3 |
| General technical data / type of voltage / of the operating voltage | AC/DC |
| General technical data / type of voltage / of the input voltage | AC/DC |
| General technical data / surge voltage resistance rated value | 6 kV |
| General technical data / protection class IP / of the enclosure | IP40 |
| General technical data / protection class IP / of the terminal | IP20 |
| General technical data / shock resistance / according to IEC 60068-2-27 | sinusoidal half-wave 15 g / 11 ms |
| General technical data / shock resistance / for railway applications according to EN 61373 | Category 1, Class B |
| General technical data / vibration resistance / according to IEC 60068-2-6 | 10 ... 500 Hz: 5 g |
| General technical data / vibration resistance / for railway applications according to EN 61373 | Category 1, Class B |
| General technical data / operating frequency maximum | 3 600 1/h |
| General technical data / mechanical service life (operating cycles) typical | 10 000 000 |
| General technical data / electrical endurance (operating cycles) typical | 10 000 000 |
| General technical data / thermal current | 10 A |
| General technical data / reference code according to IEC 81346-2 | S |
| General technical data / continuous current of the C characteristic MCB | 10 A |
| General technical data / Substance Prohibitance (day/month/year) | 10/01/2014 |
| General technical data / Net Weight | 17 g |
| operating voltage / at AC / at 50 Hz rated value | 5 ... 500 V |
| operating voltage / at AC / at 60 Hz rated value | 5 ... 500 V |
| General technical data / operating voltage / at DC rated value | 5 ... 500 V |
| contact reliability | One maloperation per 100 million (17 V, 5 mA), one maloperation per 10 million (5 V, 1 mA) |
| Auxiliary circuit / design of the contact of auxiliary contacts | Silver alloy |
| Auxiliary circuit / number of NC contacts for auxiliary contacts | 2 |
| Auxiliary circuit / lagging switching | 0 |
| Auxiliary circuit / number of NO contacts for auxiliary contacts | 0 |
| Auxiliary circuit / leading contact | 0 |
| Auxiliary circuit / operational current at AC-12 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current at AC-12 / at 48 V rated value | 10 A |
| Auxiliary circuit / operational current at AC-12 / at 110 V rated value | 10 A |
| Auxiliary circuit / operational current at AC-12 / at 230 V rated value | 8 A |
| Auxiliary circuit / operational current at AC-12 / at 400 V rated value | 8 A |
| Auxiliary circuit / operational current at AC-15 / at 24 V rated value | 6 A |
| Auxiliary circuit / operational current at AC-15 / at 48 V rated value | 6 A |
| Auxiliary circuit / operational current at AC-15 / at 110 V rated value | 6 A |
| Auxiliary circuit / operational current at AC-15 / at 230 V rated value | 6 A |
| Auxiliary circuit / operational current at AC-15 / at 400 V rated value | 3 A |
| Auxiliary circuit / operational current at AC-15 / at 500 V rated value | 1.4 A |
| Auxiliary circuit / operational current at DC-12 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current at DC-12 / at 48 V rated value | 5 A |
| Auxiliary circuit / operational current at DC-12 / at 110 V rated value | 2.5 A |
| Auxiliary circuit / operational current at DC-12 / at 230 V rated value | 1 A |
| Auxiliary circuit / operational current at DC-12 / at 400 V rated value | 0.3 A |
| Auxiliary circuit / operational current at DC-12 / at 500 V rated value | 0.3 A |
| Auxiliary circuit / operational current at DC-13 / at 24 V rated value | 3 A |
| Auxiliary circuit / operational current at DC-13 / at 48 V rated value | 1.5 A |
| Auxiliary circuit / operational current at DC-13 / at 110 V rated value | 0.7 A |
| Auxiliary circuit / operational current at DC-13 / at 230 V rated value | 0.3 A |
| Auxiliary circuit / operational current at DC-13 / at 400 V rated value | 0.1 A |
| Auxiliary circuit / operational current at DC-13 / at 500 V rated value | 0.1 A |
| Connections/ Terminals / type of electrical connection | spring-loaded terminals |
| Connections/ Terminals / type of connectable conductor cross-sections / solid without core end processing | 2x (0.25 ... 1.5 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / finely stranded with core end processing | 2x (0.25 ... 0.75 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / finely stranded without core end processing | 2x (0.25 ... 1.5 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for AWG cables | 2x (24 ... 16) |
| Ambient conditions / ambient temperature / during operation | -25 ... +70 °C |
| Ambient conditions / ambient temperature / during storage | -40 ... +80 °C |
| Ambient conditions / environmental category during operation according to IEC | 3M6, 3S2, 3B2, 3C3 (without salt spray), 3K6 (with relative humidity of 10 ... |
| Ambient conditions / 60721 | 95%, no condensation in operation permitted) |
| Installation/ mounting/ dimensions / fastening method | front plate mounting |
| Installation/ mounting/ dimensions / of modules and accessories | Front plate mounting |
| Installation/ mounting/ dimensions / height | 36 mm |
| Installation/ mounting/ dimensions / width | 9.8 mm |
| Installation/ mounting/ dimensions / depth | 49.7 mm |
| Installation/ mounting/ dimensions / suitability for integration / plastic enclosure | No |
| Installation/ mounting/ dimensions / suitability for integration / metal enclosure | No |
| Environmental footprint / Environmental Product Declaration(EPD) | Yes |
| global warming potential [CO2 eq] total | 0.787 kg |
| global warming potential [CO2 eq] during manufacturing | 0.566 kg |
| global warming potential [CO2 eq] during operation | 0.235 kg |
| global warming potential [CO2 eq] after end of life | -0.015 kg |
Item code: 3RA2816-0EW20
Item code: 3RT2035-1NB30
Item code: 6MF2805-0AA00
Item code: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.