Item code: 3RA2816-0EW20
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Màn hình HMI SIEMENS 6AV2123-2MB03-0AX0. General information / Tên kiểu sản phẩm: KTP1200 Basic color PN; Display / Design of display: TFT widescreen display, LED backlighting; Display / Screen diagonal: 12 in.
Item code
6AV2123-2MB03-0AX0
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 6AV2123-2MB03-0AX0 |
| Tên gọi chính hãng | SIMATIC HMI, KTP1200 Basic, Basic Panel, Key/touch operation, 12" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic V13, contains open-source software, which is provided free of charge see enclosed CD |
| General information / Tên kiểu sản phẩm | KTP1200 Basic color PN |
| Display / Design of display | TFT widescreen display, LED backlighting |
| Display / Screen diagonal | 12 in |
| Display / Display width | 261.1 mm |
| Display / Display height | 163.2 mm |
| Display / Number of colors | 65 536 |
| Display / Resolution (pixels) / Horizontal image resolution | 1 280 pixel |
| Display / Resolution (pixels) / Vertical image resolution | 800 pixel |
| Display / Backlighting / MTBF backlighting (at 25 °C) | 20 000 h |
| Display / Backlighting / Backlight dimmable | Yes |
| Keyboard / Function keys / Number of function keys | 10 |
| Keyboard / Function keys / Number of function keys with LEDs | 0 |
| Control elements / Keyboard / Keys with LED | No |
| Control elements / Keyboard / System keys | No |
| Control elements / Keyboard / Numeric keyboard | Yes; Onscreen keyboard |
| Control elements / Keyboard / alphanumeric keyboard | Yes; Onscreen keyboard |
| Control elements / Touch operation / Design as touch screen | Yes; Analog-resistive |
| Installation type/mounting / Mounting position | vertical |
| Installation type/mounting / Mounting in portrait format possible | Yes |
| Installation type/mounting / Mounting in landscape format possible | Yes |
| Installation type/mounting / maximum permissible angle of inclination without external ventilation | 35° |
| Supply voltage / Type of supply voltage | DC |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Input current / Current consumption (rated value) | 510 mA |
| Input current / Starting current inrush I²t | 0.2 A²·s |
| Power / Active power input, typ. | 12.2 W |
| Processor / Processor type | ARM |
| Storage / Flash | Yes |
| Storage / RAM | Yes |
| Storage / Memory available for user data | 10 Mbyte |
| Type of output / Acoustics / Buzzer | Yes |
| Type of output / Acoustics / Speaker | No |
| Time of day / Clock / Hardware clock (real-time) | Yes |
| Time of day / Clock / Software clock | Yes |
| Time of day / Clock / retentive | Yes; Back-up duration typically 6 weeks |
| Time of day / Clock / synchronizable | Yes |
| Interfaces / Number of industrial Ethernet interfaces | 1 |
| Interfaces / Number of RS 485 interfaces | 0 |
| Interfaces / Number of RS 422 interfaces | 0 |
| Interfaces / Number of RS 232 interfaces | 0 |
| Interfaces / Number of USB interfaces | 1; Up to 16 GB |
| Interfaces / Number of 20 mA interfaces (TTY) | 0 |
| Interfaces / Number of parallel interfaces | 0 |
| Interfaces / Number of other interfaces | 0 |
| Interfaces / Number of SD card slots | 0 |
| Interfaces / With software interfaces | No |
| Interfaces / Industrial Ethernet / Industrial Ethernet status LED | 2 |
| Protocols / PROFINET | Yes |
| Protocols / Supports protocol for PROFINET IO | No |
| Protocols / IRT | No |
| Protocols / PROFIBUS | No |
| Protocols / EtherNet/IP | Yes |
| Protocols / MPI | No |
| Protocols / Protocols (Ethernet) / TCP/IP | Yes |
| Protocols / Protocols (Ethernet) / DHCP | Yes |
| Protocols / Protocols (Ethernet) / DCP | Yes |
| Protocols / Protocols (Ethernet) / LLDP | Yes |
| Protocols / WEB characteristics / HTTP | No |
| Protocols / WEB characteristics / HTML | No |
| Redundancy mode / Media redundancy / MRP | No |
| Protocols / Further protocols / CAN | No |
| Protocols / Further protocols / MODBUS | Yes; Modicon (MODBUS TCP/IP) |
| Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readable | No |
| EMC / Emission of radio interference acc. to EN 55 011 / Limit class A, for use in industrial areas | Yes |
| Limit class B, for use in residential areas | No |
| Degree and class of protection / IP (at the front) | IP65 |
| Degree and class of protection / IP (rear) | IP20 |
| Degree and class of protection / NEMA (front) / Enclosure Type 4 at the front | Yes |
| Degree and class of protection / NEMA (front) / Enclosure Type 4x at the front | Yes |
| Ambient temperature during operation / Operation (vertical installation) / For vertical installation, min. | 0 °C |
| Ambient temperature during operation / Operation (vertical installation) / For vertical installation, max. | 50 °C |
| Ambient temperature during operation / Operation (max. tilt angle) / At maximum tilt angle, min. | 0 °C |
| Ambient temperature during operation / Operation (max. tilt angle) / At maximum tilt angle, max. | 40 °C |
| Ambient temperature during operation / Operation (vertical installation, portrait format) / For vertical installation, min. | 0 °C |
| Ambient temperature during operation / Operation (vertical installation, portrait format) / For vertical installation, max. | 40 °C |
| Ambient temperature during operation / Operation (max. tilt angle, portrait format) / At maximum tilt angle, min. | 0 °C |
| Ambient temperature during operation / Operation (max. tilt angle, portrait format) / At maximum tilt angle, max. | 35 °C |
| Ambient conditions / Ambient temperature during storage/transportation / min. | -20 °C |
| Ambient conditions / Ambient temperature during storage/transportation / max. | 60 °C |
| Ambient conditions / Relative humidity / Operation, max. | 90 %; no condensation |
| Operating systems / proprietary | Yes |
| Operating systems / pre-installed operating system / Windows CE | No |
| Configuration / Message indicator | Yes |
| Configuration / Alarm system (incl. buffer and acknowledgment) | Yes |
| Configuration / Process value display (output) | Yes |
| Configuration / Process value default (input) possible | Yes |
| Configuration / Recipe management | Yes |
| STEP 7 Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) |
| STEP 7 Professional (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) |
| WinCC flexible Compact | No |
| WinCC flexible Standard | No |
| WinCC flexible Advanced | No |
| WinCC Basic (TIA Portal) | Yes |
| WinCC Comfort (TIA Portal) | Yes |
| WinCC Advanced (TIA Portal) | Yes |
| WinCC Professional (TIA Portal) | Yes |
| Languages / Online languages / Number of online/runtime languages | 10 |
| Languages / Project languages / Languages per project | 32 |
Item code: 3RA2816-0EW20
Item code: 3RT2035-1NB30
Item code: GT2107-WTBD
Item code: 6MF2805-0AA00
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.