Item code: 3RA2816-0EW20
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Đế đấu nối SIEMENS 6ES7193-6BP00-0BA0. General information / Tên kiểu sản phẩm: BU type A0; General information / HW functional status: From FS06; Supply voltage / Rated value (DC): 24 V.
Item code
6ES7193-6BP00-0BA0
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 6ES7193-6BP00-0BA0 |
| Tên gọi chính hãng | SIMATIC ET 200SP, BaseUnit BU15-P16+A0+2B, BU type A0, Push-in terminals, without AUX terminals, bridged to the left, WxH: 15x 117 mm |
| General information / Tên kiểu sản phẩm | BU type A0 |
| General information / HW functional status | From FS06 |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / external protection for power supply lines | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic |
| Supply voltage / Mains filter / integrated | No |
| Current carrying capacity / For P1 and P2 bus, max. | 10 A |
| Current carrying capacity / For process terminals, max. | 2 A |
| Hardware configuration / Automatic encoding | Yes |
| Hardware configuration / Formation of potential groups / New potential group | No |
| Hardware configuration / Formation of potential groups / Potential group continued from the left | Yes |
| Hardware configuration / Slots / Number of slots | 1; Type A0 |
| Isolation / Isolation tested with | 707 V DC (type test) |
| Ambient conditions / Ambient temperature during operation / horizontal installation, min. | -30 °C |
| Ambient conditions / Ambient temperature during operation / horizontal installation, max. | 60 °C |
| vertical installation, min. | -30 °C |
| vertical installation, max. | 50 °C |
| Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Absolute humidity / dew point, min. | -60 °C; suitable for dry room applications |
| Accessories / Color coding labels / for process terminals | CC00 to CC09 |
| Accessories / Color coding labels / for AUX terminals | does not exist |
| Accessories / Color coding labels / for add-on terminals | does not exist |
| Connection method / Terminals / Terminal type | Push-in terminal |
| Connection method / Terminals / system-integrated shield connection | Yes; Optional |
| Connection method / Terminals / Conductor cross-section, min. | 0.14 mm²; AWG 26 |
| Connection method / Terminals / Conductor cross-section, max. | 2.5 mm²; AWG 14 |
| Connection method / Terminals / Number of process terminals to I/O module | 16; Pro slot |
| Connection method / Terminals / Number of terminals to AUX bus | 0 |
| Connection method / Terminals / Number of add-on terminals | 0 |
| Connection method / Terminals / Number of terminals with connection to P1 and P2 bus | 2; Pro slot |
| Dimensions / Chiều rộng | 15 mm |
| Dimensions / Chiều cao | 117 mm |
| Dimensions / Chiều sâu | 35 mm |
| Weights / Khối lượng xấp xỉ | 40 g |
Item code: 3RA2816-0EW20
Item code: 3RT2035-1NB30
Item code: 6MF2805-0AA00
Item code: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.