Item code: 3RA2816-0EW20
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Module ngõ vào số SIEMENS 6ES7521-1BH10-0AA0. General information / Tên kiểu sản phẩm: DI 16 x 24 V DC BA; General information / HW functional status: FS01; General information / Firmware version: V1.0.0.
Item code
6ES7521-1BH10-0AA0
Unit
Chưa cập nhật
Supply status
Liên hệ báo giá
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 6ES7521-1BH10-0AA0 |
| Tên gọi chính hãng | SIMATIC S7-1500/ET 200MP, digital input module, DI 16x24 V DC BA (25 mm); sinking input; 16 channels in a group; input type 3 according to IEC 61131; input delay typ. 3.2 ms; including U-connector and front connector push-in |
| General information / Tên kiểu sản phẩm | DI 16 x 24 V DC BA |
| General information / HW functional status | FS01 |
| General information / Firmware version | V1.0.0 |
| General information / FW update possible | Yes |
| General information / Product function / I&M data | Yes; I&M0 to I&M3 |
| General information / Product function / Isochronous mode | No |
| General information / Product function / Prioritized startup | Yes |
| General information / Engineering with / STEP 7 TIA Portal configurable/integrated from version | V13 / V13 |
| General information / Engineering with / STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| General information / Engineering with / PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| General information / Engineering with / PROFINET from GSD version/GSD revision | V2.3 / - |
| General information / Operating mode / DI | Yes |
| General information / Operating mode / Counter | No |
| General information / Operating mode / MSI | Yes |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Power / Power consumption from the backplane bus | 1.05 W |
| Power loss / Power loss, typ. | 1.8 W |
| Digital inputs / Số ngõ vào số | 16 |
| Digital inputs / Digital inputs, parameterizable | No |
| Digital inputs / Sourcing/sinking input | P-reading |
| Digital inputs / Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
| Digital inputs / Input voltage / Rated value (DC) | 24 V |
| Digital inputs / Input voltage / for signal "0" | -30 to +5 V |
| Digital inputs / Input voltage / for signal "1" | +11 to +30V |
| for signal "1", typ. | 2.7 mA |
| Input delay (for rated value of input voltage) / for standard inputs / parameterizable | No |
| Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", min. | 3 ms |
| Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", max. | 4 ms |
| Input delay (for rated value of input voltage) / for standard inputs / at "1" to "0", min. | 3 ms |
| Input delay (for rated value of input voltage) / for standard inputs / at "1" to "0", max. | 4 ms |
| Input delay (for rated value of input voltage) / for interrupt inputs / parameterizable | No |
| Input delay (for rated value of input voltage) / for technological functions / parameterizable | No |
| Cable length / shielded, max. | 1 000 m |
| Cable length / unshielded, max. | 600 m |
| Encoder / Connectable encoders / 2-wire sensor | Yes |
| Encoder / Connectable encoders / permissible quiescent current (2-wire sensor), max. | 1.5 mA |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | No |
| Interrupts/diagnostics/status information / Alarms / Hardware interrupt | No |
| Interrupts/diagnostics/status information / Diagnoses / Monitoring the supply voltage | No |
| Interrupts/diagnostics/status information / Diagnoses / Wire break | No |
| Interrupts/diagnostics/status information / Diagnoses / Short-circuit | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / RUN LED | Yes; green LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LED | Yes; red LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Monitoring of the supply voltage (PWR-LED) | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Channel status display | Yes; green LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / for channel diagnostics | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / for module diagnostics | No |
| Potential separation / Potential separation channels / between the channels | No |
| Potential separation / Potential separation channels / between the channels, in groups of | 16 |
| Potential separation / Potential separation channels / between the channels and backplane bus | Yes |
| Isolation / Isolation tested with | 707 V DC (type test) |
| Security / signed firmware update | No |
| Security / data integrity | No |
| Ambient conditions / Ambient temperature during operation / horizontal installation, min. | 0 °C |
| Ambient conditions / Ambient temperature during operation / horizontal installation, max. | 60 °C |
| Ambient conditions / Ambient temperature during operation / vertical installation, min. | 0 °C |
| Ambient conditions / Ambient temperature during operation / vertical installation, max. | 40 °C |
| Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Dimensions / Chiều rộng | 25 mm |
| Dimensions / Chiều cao | 147 mm |
| Chiều sâu | 129 mm |
| Weights / Khối lượng xấp xỉ | 230 g |
| Other / Note: | Supplied incl. 40-pole push-in front connectors |
Item code: 3RA2816-0EW20
Item code: 3RT2035-1NB30
Item code: 6MF2805-0AA00
Item code: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.