Item code: 3RA2816-0EW20
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Aptomat SIEMENS 5SV3346-6. Model / product brand name: SENTRON; Model / product designation: Residual current operated circuit breaker; Model / design of the product: Instantaneous.
Item code
5SV3346-6
Unit
Chưa cập nhật
Supply status
Contact for quote
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 5SV3346-6 |
| Tên gọi chính hãng | Residual current operated circuit breaker, 4-pole, type A, In: 63 A, 30 mA, Un AC: 400 V |
| Model / product brand name | SENTRON |
| Model / product designation | Residual current operated circuit breaker |
| Model / design of the product | Instantaneous |
| Model / product type designation | 5SV3 |
| General technical data / number of poles | 4 |
| General technical data / size of installation devices according to DIN 43880 | 1 |
| General technical data / mechanical service life (operating cycles) typical | 10 000 |
| General technical data / short-circuit current of series fuse maximum permissible | 100 A |
| General technical data / short-circuit current rating | 10 kA |
| General technical data / switching function short-term delayed | No |
| General technical data / degree of pollution | 2 |
| General technical data / insulation voltage (Ui) rated value | 2 000 V |
| General technical data / tripping fault current rated value | 30 mA |
| General technical data / let-through current permissible | 5 700 A |
| General technical data / I2t value permissible | 58 000 A²·s |
| Supply voltage / supply voltage for testing equipment minimum | 195 V |
| Supply voltage / value range of the supply voltage frequency | 50 Hz |
| Supply voltage / value range of the operating frequency | 50 Hz |
| Supply voltage / value range of the supply voltage at AC | 400 V |
| Protection class / protection class IP | IP20, if the distribution board is installed, with connected conductors |
| Breaking Capacity / switching capacity current / according to IEC 61008-1 rated value | 0.8 kA |
| Breaking Capacity / grid spacing | 60 mm |
| Dissipation / power loss [W] / for rated value of the current at AC in hot operating state per pole | 3.9 W |
| Dissipation / power loss [W] / maximum | 11.7 W |
| Appearance / RAL color number | 7 035 |
| Appearance / RAL color number (similar) | 7 035 |
| Product details / product feature silicon-free | Yes |
| Product details / product extension installable supplementary devices | Yes |
| Connections / connectable conductor cross-section solid / minimum | 0.75 mm² |
| Connections / connectable conductor cross-section solid / maximum | 35 mm² |
| Connections / connectable conductor cross-section stranded / minimum | 0.75 mm² |
| Connections / connectable conductor cross-section stranded / maximum | 35 mm² |
| Connections / tightening torque with screw-type terminals / minimum | 2.5 N·m |
| Connections / tightening torque with screw-type terminals / maximum | 3 N·m |
| Connections / position of power supply cord | top or bottom |
| Mechanical Design / height | 90 mm |
| Mechanical Design / width | 72 mm |
| Mechanical Design / depth | 70 mm |
| Mechanical Design / installation depth | 70 mm |
| Mechanical Design / number of modular width units | 4 |
| Mechanical Design / fastening method | DIN-rail mounting |
| Mechanical Design / mounting position | any |
| Mechanical Design / Net Weight | 374 g |
| Environmental conditions / ambient temperature during operation / minimum | -25 °C |
| Environmental conditions / ambient temperature during operation / maximum | 45 °C |
| Environmental conditions / ambient temperature during storage minimum | -40 °C |
| Environmental conditions / number of test cycles for environmental testing according to IEC 60068-2-30 | 28 |
Item code: 3RA2816-0EW20
Item code: 3RT2035-1NB30
Item code: 6MF2805-0AA00
Item code: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.