Item code: IFS203
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Bộ chủ IO-Link IFM AL1402. Application: I/O modules for field applications; Daisy-chain function: voltage supply; fieldbus interface.
Item code
AL1402
Unit
Chưa cập nhật
Supply status
Contact for quote
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | AL1402 |
| Application | I/O modules for field applications |
| Daisy-chain function | voltage supply; fieldbus interface |
| Operating voltage [V] | 20...30 DC; (US ; to PELV) |
| Current consumption [mA] | 300...3900; (US) |
| Protection class | III |
| Additional voltage supply [V] | 20...30 DC; (UA) |
| Max. current load total [A] | 8; 3.6 |
| Current rating per port [A] | 2; (adjustable: 0...2; Factory setting: 2); 2; (adjustable: 0...2; Factory setting: 0,45) |
| Total number of inputs and outputs | 16; (configurable) |
| Number of inputs and outputs | Number of digital inputs: 12; Number of digital outputs: 12 |
| Number of digital inputs | 12; (IO-Link Port Class A: 4 x 2; IO-Link Port Class B: 4 x 1) |
| Switching level high [V] | 11...30 |
| Switching level low [V] | 0...5 |
| Digital inputs protected against short circuits | yes |
| Number of digital outputs | 12; (IO-Link Port Class A: 4 x 1; IO-Link Port Class B: 4 x 2) |
| Short-circuit proof | yes |
| Max. current load per output [mA] | 2000 |
| Communication interface | Ethernet; IO-Link |
| Transmission standard | 100Base-TX |
| Transmission rate | 100 MBit/s |
| Protocol | PROFINET |
| Factory settings | IP address: 0.0.0.0; subnet mask: 0.0.0.0; gateway IP address: 0.0.0.0; MAC address: see type label |
| Note on interfaces | IO-Link Integration Edition 2; CC-C (Conformance Class C) (IRT-Switch); S2 redundancy; Netload Class III; CiR (Configuration in Run); SNMP (Simple Network Management Protocol); MRP (Media Redundancy Protocol); Supported network topologies: line; ring |
| Transmission type | COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| Number of ports class A | 4 |
| Number of ports class B | 4 |
| Ambient temperature [°C] | -25...60 |
| Storage temperature [°C] | -25...85 |
| Max. relative air humidity [%] | 90 |
| Protection | IP 65; IP 66; IP 67 |
| Protection rating (NEMA 250) | 6P |
| Pollution degree | 2 |
| Chemical media | ISO 16750-5: AA, BA, BD, HLP, CC, DB, DC, DD, CA; NEMA 250 5.13.1: AA |
| EMC | EN 61000-6-2; EN 61000-6-4 |
| Shock resistance | DIN EN 60068-2-27 |
| Vibration resistance | DIN EN 60068-2-64 2009-04; DIN EN 60068-2-6 2008-10 |
| MTTF [years] | 43 |
| Weight [g] | 412.1 |
| Housing | rectangular |
| Type of mounting | Backplane mounting |
| Dimensions [mm] | 208 x 59.3 x 38.4 |
| Material | housing: PA orange; Socket: brass nickel-plated |
| Sealing material | FKM |
| Remarks | Further information is available in the manual. |
| Pack quantity | 1 pcs. |
| Connector | 2 x M12; coding: D; Contacts: 4; sealing: FKM; 8 x M12; coding: A; Contacts: 5; sealing: FKM; 1 x M12; coding: L; Contacts: 5; 1 x M12; coding: L; Contacts: 5; sealing: FKM |
Item code: IFS203
Item code: EVT406
Item code: IG5526
Item code: II5961
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.