| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 1240840000 |
| Mã đặt hàng Weidmüller | 1240840000 |
| Model Weidmüller | IE-SW-BL05-5TX |
| UL File Number Search | [UL Website](https://database.ul.com/cgi-bin/XYV/cgifind/LISEXT/1FRAME/gfilenbr.html) |
| Delivery status | This article will no longer be available in the future. |
| Last order date | /Date(1801263600000)/ |
| Alternative product | [2908030000](~/p/2908030000) |
| Depth | 70 mm |
| Depth (inches) | 2.756 inch |
| Height | 115 mm |
| Height (inches) | 4.528 inch |
| Width | 30 mm |
| Width (inches) | 1.181 inch |
| Net weight | 175 g |
| Storage temperature | -40 °C...85 °C |
| Operating temperature | -10 °C...60 °C |
| Humidity | 5 to 95 % (non-condensing) |
| SCIP | 9229992a-00b9-4096-8962-200a7f33e289 |
| EMC standards | EN 55032 EN 55035 FCC Part 15 Subpart B Class A IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz - 6 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF: 100A/m |
| Explosive risk zone | UL/cUL, Class I, Division 2, Groups A, B, C and D ATEX Zone 2 Ex ec IIC T4 Gc EN IEC 60079-0 EN IEC 60079-7 |
| Free fall | According to IEC 60068-2-32 |
| Safety standard | UL 61010-1 UL 61010-2-201 EN 62368-1 |
| Ship use | DNV |
| Shock | according to IEC 60068-2-27 |
| Vibration | according to IEC 60068-2-6 |
| Operating temperature, max. | 60 °C |
| Operating temperature, min. | -10 °C |
| Storage temperature, max. | 85 °C |
| Storage temperature, min. | -40 °C |
| Time interval | 5 years |
| Function DIP switch | Broadcast storm protection enable/disable QoS (on/off) MAC frame filtering (on/off) |
| LED indicator | PWR1 PWR2 10/100M (TP-Port) |
| Number of ports | 5x RJ45 |
| RJ45 ports | 10/100BaseT(X) auto negotiation Full-/half-duplex mode Auto MDI/MDI-X port |
| Network traffic filter | Quality of Service (QoS) MAC frame filtering (LLDP frame blocking) |
| Industrial protocol support | PROFINET device acc. to conformance class A |
| MTBF | According to Standard: Telcordia SR-332 Operating time (hours), min.: 3,969,664 h Ambient temperature: 25 °C |
| Connection type | 1 removable 4-pin terminal block |
| Current consumption | 0.1 A at 24 V |
| Overload current protection | 1.1 A |
| Reverse polarity protection | Available |
| Supply voltage | 12/24/48 V DC 2 redundant inputs |
| Voltage supply range | Voltage type: DC Voltage, min.: 9.6 V Voltage, max.: 60 V |
| Bandwidth backplane | 1 Gbit/s |
| MAC table size | 2 K |
| Packet buffer size | 768 kbit |
| Priority queues | 4 |
| Housing main material | Aluminium |
| Protection degree | IP30 |
| Speed | Fast Ethernet |
| Switch | unmanaged |
| Type of mounting | DIN rail Panel (with optional mounting kit) |
| Data switching | Store and Forward |
| Flow control | IEEE 802.3x flow control Back pressure flow control |
| Standard | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for flow control IEEE 802.1p for Class of Service / Quality of Service (CoS/QoS) |
Item code: AMG FIM-C
Item code: AMG EP 2010
Item code: 1024300000
Item code: 1240900000
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.