Item code: ACS880-01-293A-3
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Khối tiếp điểm phụ ABB 1SBN010110R1010. Product Net Width: 9.9 mm; Product Net Depth / Length: 39.5 mm.
Item code
1SBN010110R1010
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 1SBN010110R1010 |
| Hãng sản xuất | ABB |
| Mã định danh ABB | 1SBN010110R1010 |
| Mã hàng theo CRM | CA4-10 |
| Model ABB | CA4-10 |
| Nhóm sản phẩm | Vật tư công nghiệp |
| Ghi chú xác minh | Thông tin được lấy từ dữ liệu CRM hiện có; TESFA sẽ đối chiếu lại mã hàng/cấu hình trước khi báo giá. |
| Product Net Width | 9.9 mm |
| Product Net Depth / Length | 39.5 mm |
| Product Net Height | 43 mm |
| Product Net Weight | 0.014 kg |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 1P |
| Standards | IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 60947-5-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-5-1-14 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (I e ) | (500 V) 2 A; (690 V) 2 A; (24 / 127 V) 6 A; (220 / 240 V) 4 A; (400 / 440 V) 3 A |
| Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W; (48 V) 2.8 A / 134 W; (72 V) 1 A / 72 W; (110 V) 0.55 A / 60 W; (125 V) 0.55 A / 69 W; (220 V) 0.27 A / 60 W; (250 V) 0.27 A / 68 W; (400 V) 0.15 A / 60 W; (500 V) 0.13 A / 65 W; (600 V) 0.1 A / 60 W |
| Rated Short-time Withstand Current Low Voltage (I cw ) | for 0.1 s 140 A; for 1 s 100 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-5-1 690 V; acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour; (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Power Loss | at 6 A per Pole 0.1 W |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²; Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²; Rigid 1/2x 1 ... 2.5 mm²; Rigid Solid 1/2x 1 ... 2.5 mm²; Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Suitable For | AF09; AF09Z; AF12; AF12Z; AF16; AF16Z; AF26; AF26Z; AF30; AF30Z; AF38; AF38Z; AF40; AF52; AF65; AF80; AF96; AFC09; AFC12; AFC16; AFC26; AFC30; AFC38; AFC40; AFC52; AFC65; AFC80; AFC96; AF09B; AF09ZB; AF12B; AF12ZB; AF16B; AF16ZB; AF26B; AF26ZB; AF30B; AF30ZB; AF38B; AF38ZB; AF40B; AF52B; AF65B; AF80B; AF96B; NF22E; NFZ22E; NF31E; NFZ31E; NF40E; NFZ40E; NFC22E; NFC31E; NFC40E; NFZB22E; NFB22E; NFZB31E; NFB31E; NFZB40E; NFB40E |
| Product Name | Auxiliary Contact Block |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG; Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb |
Item code: ACS880-01-293A-3
Item code: ACS880-01-032A-3
Item code: ACS880-01-072A-3
Item code: ACS880-01-045A-3
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.