Item code: 131150435
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Cảm biến an toàn điện tử Schmersal 101204613.
Item code
101204613
Unit
Chưa cập nhật
Supply status
Contact for quote
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 101204613 |
| Mã đặt hàng Schmersal | 101204613 |
| Model Schmersal | CSS 11-30S-SD-M-ST |
| Working principle | inductive |
| Housing construction form | Cylinder, thread |
| Installation conditions (mechanical) | not flush |
| Sensor topology | Sensor for series wiring |
| Housing material | Stainless steel |
| Reaction time, maximum | 60 ms |
| Duration of risk, maximum | 60 ms |
| Gross weight | 248 g |
| Serial diagnostics | Yes |
| Diagnostic output | Yes |
| Short circuit detection | Yes |
| Cross-circuit detection | Yes |
| Safety functions | Yes |
| Cascadable | Yes |
| Integral system diagnostics, status | Yes |
| Number of LEDs | 2 |
| Number of semi-conductor outputs with signaling function | 1 |
| Number of fail-safe digital outputs | 2 |
| Number of series-wiring of sensors | 31 |
| Performance Level, up to | e |
| Category | 4 |
| PFH value | 3.60 x 10−9 /h |
| Safety Integrity Level (SIL), suitable for applications in | 3 |
| Actuating panels | from head |
| Active area | front side |
| Switch distance, typical | 11 mm |
| Assured switching distance "ON" Sao | 8 mm |
| Assured switching distance "OFF" Sar | 15 mm |
| Note (switching distance) | All switching distances in accordance EN IEC 60947-5-3 |
| Hysteresis (Switching distance), maximum | 2 mm |
| Repeat accuracy R | 1 mm |
| Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
| Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
| ISO thread of the sensor | M30 |
| Length of sensor | 99.5 mm |
| IP Degree of protection | IP65 IP67 IP69 |
| Ambient temperature | -25 ... +65 °C |
| Storage and transport temperature | -25 ... +85 °C |
| Resistance to vibrations | 10 ... 55 Hz, amplitude 1 mm |
| Restistance to shock | 30 g / 11 ms |
| Protection class | II |
| Rated insulation voltage Ui | 32 VAC/DC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Operating voltage | 24 VDC -15 % / +10 % |
| No-load supply current I0, typical | 100 mA |
| Rated operating voltage | 24 VDC |
| Operating current | 600 mA |
| Required rated short-circuit current | 100 A |
| Switching frequency, approx. | 3 Hz |
| Rated operating current (safety outputs) | 250 mA |
| Output current, (fail-safe output), maximum | 0.25 A |
| Design of control elements | p-type | p-type | short-circuit proof, p-type |
| Voltage drop Ud, maximum | 0.5 V | 5 V |
| Leakage current Ir, maximum | 0.5 mA |
| Voltage, Utilisation category DC-12 | 24 VDC |
| Current, Utilisation category DC-12 | 0.25 A |
| Voltage, Utilisation category DC-13 | 24 VDC |
| Current, Utilisation category DC-13 | 0.25 A |
| Designation, Serial diagnostic SD | OUT |
| Operation current | 150 mA |
| Wiring capacitance | 50 nF |
| Interfering radiation | IEC 61000-6-4 |
| EMC rating | IEC 61000-6-2 |
| PIN 1 | 1A1 Ue: (1) |
| PIN 2 | X1 Safety input 1 |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
| PIN 5 | SD serial diagnostic output |
| PIN 6 | X2 Safety input 2 |
| PIN 7 | Y2 Safety output 2 |
| PIN 8 | IN serial diagnostic input |
| Recommendation (actuator) | CST 30S-1 |
| Recommended safety switchgear | PROTECT PSC1 SRB-E-201LC SRB-E-301ST |
| Note (General) | Evaluation requirements: The switch-off pauses of 250 μs – 1500 μs must be tolerated by the evaluation.The switch-off time of the safety sensor of 250 μs is additionally extended according the cable length and the capacity of the cable used. Typical |
Item code: 131150435
Item code: 151180590
Item code: 103040784
Item code: 101133843
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.