Item code: 060-110191
- Unit
- Cái
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Cảm biến áp suất IFM PN2093. Number of inputs and outputs: Number of digital outputs: 2; Number of analog outputs: 1; Measuring range: -1...25 bar: -14.5...362.5 psi: -0.1...2.5 MPa.
Item code
PN2093
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | PN2093 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | -1...25 bar: -14.5...362.5 psi: -0.1...2.5 MPa |
| Process connection | threaded connection G 1/4 Internal thread (DIN EN ISO 1179-2) |
| Special feature | gold-plated contacts |
| Measuring element | ceramic-capacitive pressure measuring cell |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature [°C] | -25...80 |
| Min. burst pressure | 350 bar: 5075 psi: 35 MPa |
| Pressure rating | 150 bar: 2175 psi: 15 MPa |
| Vacuum resistance | -1000 mbar: -0.1 MPa |
| Type of pressure | relative pressure; vacuum |
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | < 35 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.3 |
| Integrated watchdog | yes |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 500 |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (scalable 1:5) |
| Max. load [Ω] | 500 |
| Analog voltage output [V] | 0...10; (scalable 1:5) |
| Min. load resistance [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Analog start point | -1...20 bar: -14.5...290 psi: -0.1...2 MPa |
| Analog end point | 4...25 bar: 58...362.5 psi: 0.4...2.5 MPa |
| Set point SP | -0.85...25 bar: -12...362.5 psi: -0.085...2.5 MPa; -0.84...25 bar: -12.2...362.6 psi: -0.084...2.5 MPa |
| Reset point rP | -0.95...24.9 bar: -13.5...361 psi: -0.095...2.49 MPa; -0.95...24.9 bar: -13.7...361.1 psi: -0.095...2.49 MPa |
| Min. difference between SP and rP | 0.15 bar: 1.5 psi: 0.015 MPa; 0.11 bar: 1.5 psi: 0.011 MPa |
| In steps of | 0.05 bar: 0.5 psi: 0.005 MPa; 0.01 bar: 0.1 psi: 0.001 MPa |
| Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
| Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
| Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |
| Response time [ms] | < 1.5 |
| Delay time programmable dS, dr [s] | 0...50 |
| Damping process value dAP [s] | 0...4 |
| Damping for the analog output dAA [s] | 0...4 |
| Max. response time analog output [ms] | 3 |
| Parameter setting options | hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| SIO mode | yes |
| Required master port class | A; (when pin 2 not connected: B) |
| Supported DeviceIDs | Type of operation: DeviceID; Factory setting / CMPT = 2: 462; Status_B High Resolution / CMPT = 3: 973 |
| Note | For further information please see the IODD PDF file at "Downloads" |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis; Smart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis |
| Min. process cycle time [ms] | 2.3; 3 |
| IO-Link resolution pressure [bar] | 0.01 |
| IO-Link process data (cyclical) | Function: bit length; pressure: 14; binary switching information: 2; Function: bit length; pressure: 16; device status: 4; binary switching information: 2 |
| IO-Link functions (acyclical) | application specific tag |
| Ambient temperature [°C] | -25...80 |
| Storage temperature [°C] | -40...100 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27: 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 20 g (10...2000 Hz) |
| MTTF [years] | 138 |
| UL approval | UL approval number: J012 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g] | 238.5 |
| Housing | tubular |
| Dimensions [mm] | Ø 34 / L = 90.7 |
| Material | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM |
| Min. pressure cycles | 100 million |
| Tightening torque [Nm] | 25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating) |
| Restrictor element integrated | no (can be retrofitted) |
| Display | Display unit: 3 x LED, green (bar, psi, MPa); Switching status: 2 x LED, yellow; Measured values: alphanumeric display, red/green 4-digit |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
Item code: 060-110191
Item code: 060-117191
Item code: IFS203
Item code: EVT406
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.