Item code: IFS203
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Cảm biến điện dung IFM KG6000. Electrical design: PNP; Output function: normally open / closed; (selectable).
Item code
KG6000
Unit
Chưa cập nhật
Supply status
Contact for quote
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | KG6000 |
| Electrical design | PNP |
| Output function | normally open / closed; (selectable) |
| Sensing range [mm] | 0.5...30 |
| Communication interface | IO-Link |
| Housing | Threaded type |
| Dimensions [mm] | M18 x 1 / L = 92.5 |
| Special feature | optical setting aid |
| Medium temperature [°C] | -25...110 |
| Operating voltage [V] | 10...30 DC |
| Current consumption [mA] | < 22 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 200 |
| Switching frequency DC [Hz] | 30 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Sensing range adjustable | yes |
| Factory setting sensing range [mm] | 15 |
| Real sensing range Sr [mm] | 15 ± 10 % |
| Hysteresis [% of Sr] | 1...15 |
| Switch-point drift [% of Sr] | -10...10 |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Multiple switching signal; Function: Process data variable; Function: Device diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Min. process cycle time [ms] | 20 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter; normally open / normally closed (configurable); PNP / NPN (parametrierbar); Switch point setting; Hysteresis |
| Supported DeviceIDs | Type of operation: DeviceID; default: 798 |
| Ambient temperature [°C] | -25...80 |
| Protection | IP 65; IP 67; IP 69K |
| EMC | EN 61000-4-2: 8 kV AD / 4 kV CD; EN 61000-4-3: 10 V/m; EN 61000-4-4: 2 kV; EN 61000-4-6: 10 V; EN 55011: class B |
| Vibration resistance | DIN EN 60947-5-2: 1 mm amplitude, vibration duration 5 min., 30 min. per axis with resonance or 55 Hz |
| Shock resistance | DIN EN 60947-5-2: 30 g 6 shocks / 11 ms half-sine (x, y, z) |
| MTTF [years] | 1059 |
| UL approval | Ta: -25...60 °C; Enclosure type: Type 1; voltage supply: Limited Voltage/Current; UL approval number: D003; File number UL: E174191 |
| Weight [g] | 26.7 |
| Mounting | non-flush mountable |
| Thread designation | M18 x 1 |
| Material | housing: PBT; Nut: PBT; end cap: PC; potentiometer: POM |
| Display | Switching status: 1 x LED, yellow; Power: 1 x LED, green; Setting aid: 8 x LED, green |
| Optical setting aid | yes |
| Items supplied | lock nuts: 2 |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4 |
Item code: IFS203
Item code: EVT406
Item code: IG5526
Item code: II5961
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.