Item code: IFS203
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Cảm biến tiệm cận cảm ứng IFM GM705S. Electrical design: PNP; Output function: 2 x OSSD (A1 and A2).
Item code
GM705S
Unit
Chưa cập nhật
Supply status
Contact for quote
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | GM705S |
| Electrical design | PNP |
| Output function | 2 x OSSD (A1 and A2) |
| Enable zone [mm] | 4...20 |
| Housing | rectangular |
| Dimensions [mm] | 40 x 40 x 66 |
| Special feature | gold-plated contacts |
| Type of operation | continuous operation (maintenance-free) |
| Safety-related sub-function | safe state when properly undamped |
| Application | Industrial applications |
| Operating voltage [V] | 19.2...30 DC |
| Rated insulation voltage [V] | 30 |
| Current consumption [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 5000 |
| Max. voltage drop switching output DC [V] | 2.5; (100 mA) |
| Output data | Interface type C class 0 |
| Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2, 3 |
| Short-circuit protection | yes |
| Max. capacitive load CL_max [nF] | 20 |
| Safe switching-off distance s(ar) [mm] | 45 |
| Response time to safety request [ms] | 50 |
| Response time when approaching the enable zone [ms] | 200 |
| Risk time (response time for safety-related faults) [ms] | 100 |
| Applications | Class C to EN 60654-1 weatherproof application |
| Ambient temperature [°C] | -25...60; 10...40 |
| Note on ambient temperature | operational life ≤ 87600 h; operational life ≤ 175200 h |
| Rate of temperature change [K/min] | 0.5 |
| Max. relative air humidity [%] | briefly: 5...95 %; permanent: 5...70 % |
| Air pressure [kPa] | 80...106 |
| Max. height above sea level [m] | 2000 |
| Ionizing radiation | not permissible |
| Salt spray | no |
| Protection | IP 65; IP 67 |
| EMC | IEC 60947-5-2; IEC 60947-5-3; EN 60947-5-3; EN 61000-4-2 ESD: 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 20 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; EN 61000-4-8: 30 A/m; EN 55011: class B |
| Shock resistance | IEC 60947-5-2 |
| Vibration resistance | IEC 60947-5-2 |
| Complies with the requirements | ISO 13849-1: 2015 Category 3, PL e; IEC 61508 SIL 3; IEC 62061 SIL 3 |
| MIssion time TM [h] | ≤ 175200 |
| Mission time TM (additional indication) | 20 years |
| PFH [1/h] | 1E-08 |
| Weight [g] | 355 |
| Mounting | non-flush mountable |
| Material | PPE; diecast zinc |
| Display | Power: 1 x LED, green; signal: 1 x LED, yellow |
| Remarks | Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37K) 60x60x1 mm |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
Item code: IFS203
Item code: EVT406
Item code: IG5526
Item code: II5961
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.