Item code: NBN40-L2-E2-V1
- Unit
- Cái
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Cảm biến lưu lượng IFM SBG233. Number of inputs and outputs: Number of digital outputs: 2; Number of analog outputs: 1; Measuring range: 0.5...25 l/min: 0.03...1.5 m³/h.
Item code
SBG233
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | SBG233 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | 0.5...25 l/min: 0.03...1.5 m³/h |
| Process connection | threaded connection G 1/2 Internal thread |
| Special feature | gold-plated contacts |
| Application | for industrial applications |
| Media | Liquids; water; glycol solutions; Coolants |
| Note on media | oil 1 with viscosity: 10 mm²/s (40 °C); oil 2 with viscosity: 46 mm²/s (40 °C) |
| Medium temperature [°C] | -10...100 |
| Min. burst pressure [bar] | 160 |
| Pressure rating | 40 bar: 4 MPa |
| MAWP (for applications according to CRN) [bar] | 40 |
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; frequency signal; IO-Link; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C)) |
| Switching cycles (mechanical) | 10 million |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output [Hz] | 0...10000 |
| Display range | 0...30 l/min: 0...1.8 m³/h |
| Resolution | 0.1 l/min: 0.01 m³/h |
| Set point SP | 0.2...25 l/min: 0.01...1.5 m³/h |
| Reset point rP | 0...24.8 l/min: 0...1.49 m³/h |
| Frequency end point, FEP | 1.7...25 l/min: 0.1...1.5 m³/h |
| In steps of | 0.1 l/min: 0.01 m³/h |
| Frequency at the end point FRP [Hz] | 10...10000 |
| Measuring dynamics | 1:50 |
| Measuring range [°C] | -10...100 |
| Display range [°C] | -32...122 |
| Resolution [°C] | 1 |
| Set point SP [°C] | -9...100 |
| Reset point rP [°C] | -10...99 |
| In steps of [°C] | 1 |
| Frequency start point, FSP [°C] | -10...78 |
| Frequency end point, FEP [°C] | 12...100 |
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 0,5 l/min; medium and operating temperature: +22 °C ± 4K) |
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,029 °C / K |
| Accuracy [K] | 3 K (25°C; Q > 1 l/min) |
| Response time [s] | 0.01 |
| Damping process value dAP [s] | 0...5 |
| Damping for the analog output dAA [s] | 0...5 |
| Dynamic response T05 / T09 [s] | T09 = 120 (Q > 1 l/min) |
| Parameter setting options | hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 3.2 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 561 |
| Ambient temperature [°C] | 0...60 |
| Note on ambient temperature | medium temperature < 80 °C; medium temperature < 100 °C: 0...40 °C |
| Storage temperature [°C] | -15...80 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27: 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 145 |
| UL approval | UL approval number: I005; File number UL: E174189 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g] | 750 |
| Material | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts) | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Display | Display unit: 3 x LED, green; Switching status: 2 x LED, yellow; Measured values: alphanumeric display, red/green 4-digit; Programming: alphanumeric display, 4-digit |
| Remarks | Use of 200 micron filtration is recommended.; All data refer to water (20 °C).; MW = Measured value; MEW = Final value of the measuring range |
| Notes | Please note the changed housing design! |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
Item code: NBN40-L2-E2-V1
Item code: ODS10L1.8/LAK-M12
Item code: BNS 260-11ZG-ST-L
Item code: 067B3342
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.