Item code: XB5AA31
- Unit
- Cái
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Aptomat SCHNEIDER GV3P50. Range: TeSys Deca; Product name: TeSys GV3.
Item code
GV3P50
Unit
Cái
Supply status
Liên hệ báo giá
Required quantity (Cái)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Dòng sản phẩm | TeSys GV3 |
| Mã sản phẩm | GV3P50 |
| Loại thiết bị | Aptomat bảo vệ động cơ nhiệt-từ |
| Range | TeSys Deca |
| Product name | TeSys GV3 |
| Số cực | 3P |
| Dòng định mức | 50 A tại 690 V |
| Product or component type | Motor circuit breaker |
| Dải chỉnh bảo vệ nhiệt | 37–50 A |
| Device short name | GV3P |
| Device application | Motor protection |
| Ngưỡng tác động bảo vệ từ | 14 × In |
| Công suất động cơ tham chiếu | 22 kW tại 400 V |
| Trip unit technology | Thermal-magnetic |
| Khả năng cắt giới hạn Icu | 50 kA tại 400 V |
| Poles description | 3P |
| Kiểu đấu nối | Vít EverLink BTR |
| Network type | AC |
| Kiểu thao tác | Núm xoay |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Độ bền thao tác AC-3 | 50.000 chu kỳ |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 22 kW at 400/415 V AC 50/60 Hz 30 kW at 500 V AC 50/60 Hz 45 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Rotary handle |
| [In] rated current | 50 A |
| Thermal protection adjustment range | 37…50 A conforming to IEC 60947-2 |
| Magnetic tripping current | 700 A |
| [Ith] conventional free air thermal current | 50 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 8 W |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles for AC-3 at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Tightening torque | 5 N.m - on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) |
| Mounting position | Horizontal Vertical |
| Width | 55 mm |
| Height | 132 mm |
| Depth | 136 mm |
| Net weight | 0.96 kg |
| Colour | Dark grey |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ |
| Product certifications | CB Scheme CE UKCA CCC cULus EAC ATEX LROS (Lloyds register of shipping) BV ABS DNV-GL |
| IK degree of protection | IK09 enclosure |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 15 Gn for 11 ms contactor open Shocks: 30 Gn for 11 ms contactor closed Vibrations: 4 Gn, 5...300 Hz |
| Operating altitude | 3000 m |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.200 cm |
| Package 1 Width | 14.500 cm |
| Package 1 Length | 16.000 cm |
| Package 1 Weight | 1.002 kg |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 120 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 135.600 kg |
Item code: XB5AA31
Item code: XB5AA42
Item code: LRD21
Item code: XB5AD33
Hiểu vai trò rơ le nhiệt, dải chỉnh, cấp tác động, reset và phối hợp contactor; chuẩn bị thông tin đúng trước khi đặt mua.
Đọc datasheet theo mã đầy đủ, điều kiện công bố, giới hạn và bản vẽ; lập bảng đối chiếu rõ trước khi đặt vật tư công nghiệp.
Chọn contactor động cơ theo dòng tải, cấp sử dụng, điện áp coil, chế độ đóng cắt và phối hợp bảo vệ; kèm checklist yêu cầu báo giá.