For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

Module truyền thông SIEMENS 6ES7155-6MU01-0CN0. General information / Tên kiểu sản phẩm: IM 155-6 MF HF; General information / Firmware version: V6.4.1; General information / FW update possible: Yes.
Item code
6ES7155-6MU01-0CN0
Unit
Chưa cập nhật
Supply status
Contact for quote
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã sản phẩm | 6ES7155-6MU01-0CN0 |
| Tên gọi chính hãng | SIMATIC ET 200SP MultiFieldbus interface module IM 155-6 MF High Feature, PN IO, Ethernet IP, Modbus TCP, max. 64 I/O modules and 16 ET 200AL modules, S2 redundancy, multi hot swap, 0.25 ms, isochronous mode, optional PN strain relief PN security class 1 including server module (6ES7193-6PA00-0AA0) |
| General information / Tên kiểu sản phẩm | IM 155-6 MF HF |
| General information / Firmware version | V6.4.1 |
| General information / FW update possible | Yes |
| General information / Vendor identification (VendorID) | 002AH |
| General information / Device identifier (DeviceID) | 0313H |
| General information / Manufacturer ID according to ODVA (VendorID) | 0x04E3 |
| General information / Device ID according to ODVA (Product code) | 0FA2H |
| General information / Product function / I&M data | Yes; I&M0 to I&M4 |
| General information / Product function / Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| General information / Product function / Isochronous mode | Yes |
| General information / Product function / IRT | Yes |
| General information / Product function / Tool changer | Yes; Docking station and docking unit |
| General information / Product function / Local coupling, IO data | Yes |
| General information / Product function / Number of coupling modules | 6; 1x output + max. 5x input |
| General information / Engineering with / STEP 7 TIA Portal configurable/integrated from version | V20 |
| General information / Engineering with / STEP 7 configurable/integrated from version | V5.7 SP3 |
| General information / Engineering with / PROFINET from GSD version/GSD revision | GSDML V2.45 |
| General information / Engineering with / Multi Fieldbus Configuration Tool (MFCT) | V1.5.2.0 or higher |
| Configuration control / via dataset | Yes |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Supply voltage / Reverse polarity protection | Yes |
| Supply voltage / Short-circuit protection | Yes |
| Supply voltage / Mains buffering / Mains/voltage failure stored energy time | 10 ms |
| Input current / Current consumption (rated value) | 550 mA |
| Input current / Current consumption, max. | 650 mA |
| Input current / Inrush current, max. | 1 A |
| Input current / I²t | 0.05 A²·s |
| Power loss / Power loss, typ. | 2 W |
| Address space per module / Address space per module, max. | 288 byte; For input and output data respectively |
| Address space per station / Address space per station, max. | 1 440 byte |
| Hardware configuration / Rack / Quantity of operable ET 200SP modules, max. | 64 |
| Hardware configuration / Rack / Quantity of operable ET 200AL modules, max. | 16 |
| Hardware configuration / Submodules / Number of submodules per station, max. | 256 |
| Interfaces / Transmission procedure | 100BASE-TX |
| Interfaces / Số giao diện PROFINET | 1; 2 ports (switch) |
| 1. Interface / Interface types / RJ 45 (Ethernet) | Yes; with BusAdapter |
| 1. Interface / Interface types / Number of ports | 2; with BusAdapter |
| 1. Interface / Interface types / integrated switch | Yes |
| 1. Interface / Interface types / BusAdapter (PROFINET) | Yes; BA 2x RJ45, BA 2x M12, BA 2x FC |
| 1. Interface / Protocols / PROFINET IO Device | Yes |
| 1. Interface / Protocols / Open IE communication | Yes |
| 1. Interface / Protocols / Media redundancy | Yes; PROFINET MRP client |
| PROFINET IO Device / Services / IRT | Yes; 250 μs to 4 ms in 125 μs frame |
| PROFINET IO Device / Services / Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Device / Services / Fast Forwarding | Yes |
| PROFINET IO Device / Services / Fragmentation | Yes |
| PROFINET IO Device / Services / PROFIenergy | Yes |
| PROFINET IO Device / Services / Prioritized startup | Yes |
| PROFINET IO Device / Services / Shared device | Yes |
| PROFINET IO Device / Services / Number of IO Controllers with shared device, max. | 14; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| Interface types / RJ 45 (Ethernet) / Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
| Interface types / RJ 45 (Ethernet) / 100 Mbps | Yes |
| Interface types / RJ 45 (Ethernet) / Autonegotiation | Yes |
| Interface types / RJ 45 (Ethernet) / Autocrossing | Yes |
| Protocols / Supports protocol for PROFINET IO | Yes |
| Protocols / PROFIsafe | Yes |
| Protocols / PROFIBUS | No |
| Protocols / EtherNet/IP | Yes |
| Protocols / Modbus TCP | Yes |
| Protocols / Number of connections / Number of MtM communication relationships/connections, max. | 16 |
| Protocols / Redundancy mode / PROFINET system redundancy (S2) | Yes; NAP S2 |
| Protocols / Redundancy mode / PROFINET system redundancy (R1) | No |
| Protocols / Redundancy mode / H-Sync forwarding | Yes |
| Redundancy mode / Media redundancy / MRP | Yes |
| Redundancy mode / Media redundancy / MRPD | Yes |
| EtherNet/IP / Services / CIP Implicit Messaging | Yes |
| EtherNet/IP / Services / CIP Explicit Messaging | Yes |
| CIP Safety | No |
| Configuration control via Explicit Messaging | No |
| Shared device | Yes; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| Number of scanners with shared device, max. | 2 |
| Updating times / Requested Packet Interval (RPI) | 2 ms |
| Address area / Address space per module, max. | 288 byte; (246 byte outputs / 288 byte inputs) |
| Address area / ForwardOpen (Class1 & 32 bit Header) | 500 byte; (246 byte outputs / 500 byte inputs) |
| Address area / LargeForwardOpen (Class3) | 4 002 byte |
| Connections / Number of rack connections | 2 |
| Modbus TCP / Services / read coils (code=1) | Yes |
| Modbus TCP / Services / read discrete inputs (code=2) | Yes |
| Modbus TCP / Services / Read Holding Registers (Code=3) | Yes |
| Modbus TCP / Services / Read Input Register (Code=4) | Yes |
| Modbus TCP / Services / write single coil (code=5) | Yes |
| Modbus TCP / Services / Write Single Register (Code=6) | Yes |
| Modbus TCP / Services / write multiple coils (code=15) | Yes |
| Modbus TCP / Services / Write Multiple Registers (Code=16) | Yes |
| Modbus TCP / Services / Read/Write Multiple Registers (Code=23) | Yes |
| Modbus TCP / Services / Parameter change by master | Yes |
| Modbus TCP / Services / Modbus TCP Security Protocol | No |
| Modbus TCP / Address space per station / Address space per station, max. | 500 byte; (246 byte outputs / 500 byte inputs) |
| Modbus TCP / Address space per station / Access-consistent address space | 250 byte; (246 byte outputs / 250 byte inputs) |
| Modbus TCP / Updating time / I/O request interval | 2 ms |
| Modbus TCP / Connections / number of connections per device | 9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info) |
| Open IE communication / TCP/IP | Yes |
| Open IE communication / UDP | Yes |
| Open IE communication / SNMP | Yes |
| Open IE communication / LLDP | Yes |
| Open IE communication / ARP | Yes |
| Open IE communication / IGMP | Yes |
| Open IE communication / Multicast | Yes |
Item code: 3RA2816-0EW20
Item code: 3RT2035-1NB30
Item code: 6MF2805-0AA00
Item code: 6ES7440-1CS00-0YE0
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.