Item code: XB5AA31
- Unit
- Cái
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

power meter PowerLogic PM5110, modbus, up to 15th Harmonic, 1DO 33 alarms Schneider METSEPM5110. Ảnh và thông số được xác minh từ trang sản phẩm và datasheet chính thức Schneider Electric cho đúng full model.
Item code
METSEPM5110
Unit
Chưa cập nhật
Supply status
Liên hệ báo giá
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Mã đặt hàng | METSEPM5110 |
| Range | PowerLogic |
| Product name | PowerLogic PM5000 |
| Product or component type | Power meter |
| Device short name | PM5110 |
| Power quality analysis | up to the 15th harmonic |
| Device application | Power monitoring |
| Type of measurement | Current |
| [Us] rated supply voltage | 90...450 V AC 45...65 Hz |
| Network frequency | 50 Hz |
| [In] rated current | 1 A |
| type of network | 1P + N |
| Ride-through time | 80 ms 120 V AC typical |
| Display type | Monochrome graphic LCD |
| Display resolution | 128 x 128 pixels |
| Sampling rate | 64 samples/cycle |
| Measurement current | 50…8500 mA |
| Analogue input type | Voltage (impedance 5 MOhm) |
| Measurement voltage | 35…760 V AC 45...65 Hz between phases |
| Frequency measurement range | 45…65 Hz |
| Number of inputs | 0 |
| Measurement accuracy | Active energy +/- 0.5 % |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
| Number of outputs | 1 digital |
| Communication port protocol | Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, |
Item code: XB5AA31
Item code: XB5AA42
Item code: LRD21
Item code: XB5AD33
Chọn cáp cảm biến M8/M12 theo đầu đực/cái, số cực, coding, sơ đồ chân và môi trường. Có hình minh họa, bảng kiểm và mẫu yêu cầu báo giá.
Cách lập bảng tải 24VDC, xét tải đồng thời, dòng khởi động và giảm định mức; chuẩn bị hồ sơ chọn nguồn tủ điện.
Đối chiếu mã dây curoa, tiết diện, quy ước chiều dài, puly và số dây trên bộ truyền trước khi đặt mua thay thế.