Item code: E40H8-100-3-T-24
- Unit
- Chưa cập nhật
Loading content…
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.

TNS-42CC-NS-026 - 2-DOF PID Temperature Controllers (Program/Fixed Control). Ảnh và thông số được xác minh trực tiếp từ trang model chính hãng Autonics.
Item code
TNS-42CC-NS-026
Unit
Chưa cập nhật
Supply status
Liên hệ báo giá
Required quantity (Chưa cập nhật)
No online payment is required. TESFA will verify the item code, quantity, supply conditions and respond with a quotation using your contact details.
For MRO items, verifying the correct code matters more than selecting by image. TESFA checks the key technical points before confirming a quotation.
| Attribute | Product specification |
|---|---|
| Model Autonics | TNS-42CC-NS-026 |
| Power voltage | 100-240VAC~ 50/60Hz |
| Power consumption | Max. 8VA |
| Display method | 11 segment, LCD type (operating value display part: 7 segment) |
| Sampling cycle | 50 / 100 / 250 ms (parameter) |
| Option input_CT input | • 0.0-50.0 A (primary current measurement range)• CT ratio: 1/1 |
| Control output_Current | DC 0 - 20 mA or DC 4 - 20 mA (parameter), Load resistance: ≤ 500 Ω |
| Option output_Alarm | 250VAC~ 3A 1a |
| Option output_Trans. | DC 4 - 20 mA (load resistance: ≤ 500 Ω, output accuracy: ±0.3% F.S.) |
| Control type_Type | ON/OFF, P, PI, PD, PID |
| Control type_Multi SV | ≤ 4 SV |
| Control type_Group PID | ≤ 8 group |
| Control type_Zone PID | 4 zones |
| Control type_ARW | 50 to 200 % |
| Hysteresis | • Thermocouple, RTD: 1 to 100 (0.1 to 100.0) ℃/℉• Analog: 1 to 100 digit |
| Dielectric strength | Between primary terminal and case: 3,000 VAC~ 50/60 Hz for 1 min |
| Vibration | 0.75 mm amplitude at frequency of 5 to 55 Hzin each X, Y, Z direction for 2 hours |
| Relay life cycle_Mechanical | • OUT1/2: ≥ 5,000,000 operations• AL1/2/3/4/5/6: ≥ 20,000,000 operations |
| Relay life cycle_Electrical | • OUT1/2: ≥ 200,000 operations• AL1/2/3/4/5/6: ≥ 100,000 operations |
| Insulation resistance | ≥ 100 MΩ (500 VDC@(=) megger) |
| Insulation type | Double insulation or reinforced insulation (mark: @(INS), dielectric strength between the measuring input part and the power part: 3 kV) |
Item code: E40H8-100-3-T-24
Item code: AT8SDN
Item code: BA2M-DDT
Item code: BW40-12
Hướng dẫn đọc mã van điện từ SMC dòng SY3000, SY5000, SY7000 và SY9000 theo catalog hãng, kèm ví dụ SKU thật và checklist tránh đặt nhầm cấu hình.
Theo đường đi của khí nén để hiểu tiền điện đến từ đâu, tính thử chi phí và chuẩn bị checklist kiểm tra rò rỉ trong nhà máy.
Chọn ống khí PU/PA theo kích thước, áp suất tại nhiệt độ dùng, bán kính uốn và môi trường. Có bảng đối chiếu và checklist thay ống MRO.